W dniu 30.04.2024 o 12:45, Jack Zukt pisze:
Hi all,
I am cross-posting this to IBM-Main and RACF-L
A strange situation was related to me yesterday.
An ICETOOL job was executing using a tape file for work space as the input
files are quite large. As one tape was not enough, a mount for a second one
was issued. When that happened, RACF prevented the use of that second tape:
IEC501A M 2667,SCRTCH,SL,COMP,PCXDS105,ICCL105A
ICH408I USER(BATUSR ) GROUP(GRPBAT ) NAME(USERID FOR BATCH JOBS)
SYS24120.T041826.RA000.PCXDS105.TEMP1.H01 CL(DATASET ) VOL(LH6140)
INSUFFICIENT ACCESS AUTHORITY
ACCESS INTENT(UPDATE ) ACCESS ALLOWED(NONE )
IEC518I SOFTWARE ERRSTAT: RACFPROT 2667,LH6140,SL,PCXDS105,ICCL105A
Any idea why this might be happening?
The TAPEVOL classe is inactive. The TEMPDSN class is active.
Well... This is very first time I see temporary dataset on tape. I feel
like an archaeologist :-)
However it seems like the dataset is considered as regular, not
temporary. Which is wrong.
BTW: what is your SETR TAPEDSN setting?
Few remarks:
- tape protection depends on RACF and SMS and tape management system
(DFSMSrmm, CA-1, Control-T, etc.). There are many knobs and buttons.
- you can try to use regular (named) dataset on the tape. That gives you
better control over DSN.
- (obvious) why not DASD?
--
Radoslaw Skorupka
Lodz, Poland
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN