Hi all,

I am cross-posting this to IBM-Main and RACF-L
A strange situation was related to me yesterday.
An ICETOOL job was executing using a tape file for work space as the input
files are quite large. As one tape was not enough, a mount for a second one
was issued. When that happened, RACF prevented the use of that second tape:

IEC501A M 2667,SCRTCH,SL,COMP,PCXDS105,ICCL105A
ICH408I USER(BATUSR  ) GROUP(GRPBAT ) NAME(USERID FOR BATCH JOBS)
  SYS24120.T041826.RA000.PCXDS105.TEMP1.H01 CL(DATASET ) VOL(LH6140)
  INSUFFICIENT ACCESS AUTHORITY
  ACCESS INTENT(UPDATE )  ACCESS ALLOWED(NONE   )
IEC518I SOFTWARE ERRSTAT: RACFPROT 2667,LH6140,SL,PCXDS105,ICCL105A

Any idea why this might be happening?
The TAPEVOL classe is inactive. The TEMPDSN class is active.

Regards
Jack

----------------------------------------------------------------------