Hi all, I am cross-posting this to IBM-Main and RACF-L A strange situation was related to me yesterday. An ICETOOL job was executing using a tape file for work space as the input files are quite large. As one tape was not enough, a mount for a second one was issued. When that happened, RACF prevented the use of that second tape:
IEC501A M 2667,SCRTCH,SL,COMP,PCXDS105,ICCL105A ICH408I USER(BATUSR ) GROUP(GRPBAT ) NAME(USERID FOR BATCH JOBS) SYS24120.T041826.RA000.PCXDS105.TEMP1.H01 CL(DATASET ) VOL(LH6140) INSUFFICIENT ACCESS AUTHORITY ACCESS INTENT(UPDATE ) ACCESS ALLOWED(NONE ) IEC518I SOFTWARE ERRSTAT: RACFPROT 2667,LH6140,SL,PCXDS105,ICCL105A Any idea why this might be happening? The TAPEVOL classe is inactive. The TEMPDSN class is active. Regards Jack ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN