Unless LE has changed, this is my understanding 1) LE Traps any abends - does some stuff, then returns control to the abend process 2) The IPCS LEDATA is needed in some cases to go back to the CEE and DSA control blocks to find out what the real abend was.
If my understanding is incorrect, I hope someone will correct this. If it is correct then the LE CRIME SCENE INVESTIGATION Share presentation should help in identifying this issue. If there is an S0C4 before the S0C7 and it is in a WER process, contact Syncsort for assistance. They have always been great even if it is not their issue. Lizette -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Mowry, Norma E CIV DISA ESB (US) Sent: Friday, July 05, 2013 4:53 AM To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Question on how to debug S0C7 (data exception) abend Sorry, This is a batch job, executing a COBOL Program, it looks like the program is doing an internal sort using syncsort. I can see in the dump the statement failing is a ZAP, but also say a S0C4 abend before the S0C7 abend. It seemed to me that the registers associated with the ZAP were bad. The programmers are going to re-compile the program and test again. Norma Mowry DECC-Mechanicsburg Operating Systems Support (ESB11) (717)-605-7865 DSN:430 e-mail address: norma.e.mowry....@mail.mil -----Original Message----- From: IBM Mainframe Discussion List [mailto:IBM-MAIN@LISTSERV.UA.EDU] On Behalf Of Steve Comstock Sent: Wednesday, July 03, 2013 08:44 To: IBM-MAIN@LISTSERV.UA.EDU Subject: Re: Question on how to debug S0C7 (data exception) abend On 7/3/2013 5:10 AM, Mowry, Norma E CIV DISA ESB (US) wrote: > We have a production job that is abending with S0C7 reason 00000007. I > set a slip to capture a dump but I can't seem to find the input record that is causing the S0C7 in this dump. I also have a CEEDUMP but that's not real helpful in diagnosing the issue. I looked a setting a slip with a trace but don't think that will do any good to get to the problem record. > > Norma Mowry > Way too little information to help. Is this batch or online? What language is it written in? What version of z/OS? Other messages around the time of the abend? etc. Kind regards, -Steve Comstock ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN