Elardus, Thanks. I have plenty of examples of that. Not a problem. I appreciate that offer though. These will all be 3rd party calls.
To really complete a job that CA has not done, I am going to have to do a couple of SAF calls. Will need a call for OPERCMDS to validate authority to issue the command they want, and then for JES commands that affect JOB/STC/TSU do they also have authority through JESSPOOL facility to modify these jobs. All this would be much simpler, if the operator commands were being issued under the ACEE of the user, not the Roscoe region. Then there would be nothing to do in any exits.... -----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of Elardus Engelbrecht Sent: Tuesday, March 11, 2014 9:28 AM To: [email protected] Subject: Re: CA-Roscoe shops around? Jousma, David wrote: >CA does provide a very simple exit to allow for authority checks, but is very >rudimentary, and uses a hardcoded ID table. Hardcoded table???? Horrible! Thats so ancient... ;-) >What I am looking for is if someone has already written code to do appropriate >SAF checks on OPERCMDS. I hate to re-invent the wheel, but will if necessary. I can provide you a sample source code of RACROUTE REQUEST=AUTH macro if you wish. Just say whether you want first or third party checks. Also do you want to pass the entity name or the profile? Is that exit RENT or not? REUS or not? Groete / Greetings Elardus Engelbrecht ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN This e-mail transmission contains information that is confidential and may be privileged. It is intended only for the addressee(s) named above. If you receive this e-mail in error, please do not read, copy or disseminate it in any manner. If you are not the intended recipient, any disclosure, copying, distribution or use of the contents of this information is prohibited. Please reply to the message immediately by informing the sender that the message was misdirected. After replying, please erase it from your computer system. Your assistance in correcting this error is appreciated. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN