Thanks everyone for your inputs . I was able to locate the unit address .
Appreciate your help !


On Sat, Mar 15, 2014 at 1:46 AM, Ed Finnell <[email protected]> wrote:

> What I do is use DEVSERV(DS)  QD to map ranges before and after with
> VALIDATE. Cut and paste into Excel for SSID map.
>
> {QDASD},{?                                                              }
>
> {QD   } {{[s]dddd[,1]|,VOL=volser}[,NOIO{[,UCB][,DCE][,SSSCB][,DPCT]}]  }
>
> |[[,UCB][,DCE][,SSSCB][,DPCT]+
> [,RDC][,RCD][,SNSS][.RDFEATS]]
> {[s]dddd,nnn [ ,MACH={mmpp-sssss|XXXX-sssss}]                   }
>
> |,SSID={ssid | ALL}
>
> |,TYPE={type | ALL}
>
> |,CHPID=chpid
>
> {MACH={mmpp-sssss|XXXX-sssss}                                   }
>
> {SSID={ssid | ALL}                                              }
>
> {TYPE={type | ALL}                                              }
>
> {VOL=volser[ ,dddd[,nnn]]                                       }
>
> [,ONLINE][,OFFLINE][,DEFINED][,CHKFAIL][,VALIDATE][,TOTALCYL][,ATTRIBUTE]
>
>
> In a message dated 3/14/2014 7:49:23 A.M. Central Daylight Time,
> [email protected] writes:
>
> Just  look for a range of UCBs or VOLSER Mask.  Select BOTH OFFLINE or
> ONLINE
> for your scan
>
>
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to