On Thu, 12 Jun 2014 06:57:29 -0500, Dana Mitchell <[email protected]> wrote:
>On Thu, 12 Jun 2014 09:09:51 +0530, Mainframe Mainframe ><[email protected]> wrote: > >>So, sharing IODF dataset also will be same way.. or do we have some other >>process for doing this. >> > > >The IODF only needs to be catalogged on the system(s) that are used to >create/maintain them. During IPL, the master catalog is not used to locate >the IODF, just name and device address. > Umm... ever hear of dynamic activate? :-) The IODF must be cataloged on every system unless you always want to IPL for even an MVS only change (like EDT). Regards, Mark -- Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS ITIL v3 Foundation Certified mailto:[email protected] Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html Systems Programming expert at http://search390.techtarget.com/ateExperts/ ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN