On Thu, 19 Jun 2014 21:32:18 +0530, Mainframe Mainframe 
<[email protected]> wrote:

>Yes, we also start using BLSJPRMI,SUB=MSTR as IPL time, but I was getting
>issue as I mentioned in last email, So I tried starting again manually.
>But to test the error I defined
>
>//SYSTSPRT DD DUMMY  to //SYSTSPRT DD SYSOUT=*
>
Ok you have confused me but you can't add a JES2 DD and start it SUB=MSTR (you 
would have to start it under the JES subsystem without SUB=MSTR).

For us the BLSSECT is in the IBM parmlib (SYS1.IBM.PARMLIB(BLSCECT)) and the 
IBM parmlib is defined in LOADxx as part of the logical parmlib. 

Is that the same as for you ?

Doug

----------------------------------------------------------------------