IEC141I 013-C8?
C8 One of the following events occurred:
o The open subsystem module was passed an error return code in
register 15 after issuing the IEFSSREQ macro to connect the
access method control block (ACB) to the subsystem. This
indicates that the subsystem was not operating, unless the
recovery routine recovered from a prior program check.
o IEFSSREQ failed. SMS is not available.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Mainframe Mainframe
Sent: Thursday, June 19, 2014 11:22 AM
To: [email protected]
Subject: BLSJPRMI Startup issue
While Starting START BLSJPRMI address space, I am getting below error.This is
newly defined z/OS 2.1 system
IEF196I IEC141I 013-C8,IGG0193K,BLSJPRMI,BLSJPRMI,SYSTSPRT
IEC141I 013-C8,IGG0193K,BLSJPRMI,BLSJPRMI,SYSTSPRT 126 IEF196I IEA995I SYMPTOM
DUMP OUTPUT IEF196I SYSTEM COMPLETION CODE=013 REASON CODE=000000C8 IEF196I
TIME=17.08.01 SEQ=00019 CPU=0000 ASID=001D
IEF196I PSW AT TIME OF ERROR 075C1000 80BB7926 ILC 2 INTC 0D
IEF196I NO ACTIVE MODULE FOUND
IEF196I NAME=UNKNOWN
IEF196I DATA AT PSW 00BB7920 - 41003038 0A0DB20A 00509808
IEF196I AR/GR 0: 006F84E8/00BB7B34 1: 00000000/A4013000
IEF196I 2: 00000000/0000C638 3: 00000000/00BB7AFC
IEF196I 4: 00000000/006CE410 5: 00000000/00BCE000
IEF196I 6: 00000000/006CE74C 7: 00000000/006CE7A4
IEF196I 8: 00000000/006CE76C 9: 00000000/006CDEC0
IEF196I A: 00000000/00000000 B: 00000000/00BB75B2
IEF196I C: 00000000/80BB780E D: 00000000/7F602CE8
IEF196I E: 00000000/00BB75B2 F: 00000000/000000C8
IEF196I END OF SYMPTOM DUMP
*BLS001E UNABLE TO PROCESS SYS1.PARMLIB(BLSCECT) FOR SNAP IEF196I BLS001E
UNABLE TO PROCESS SYS1.PARMLIB(BLSCECT) FOR SNAP
When I checked BLS001E message and to isolate this issues, I added SYSTSPRT DD
SYSOUT=* on proc and
//IEFPROC EXEC PGM=BLSQPRMI,REGION=4096K,TIME=1440
//* SYSTSPRT DD DUMMY
//SYSTSPRT DD SYSOUT=*
//SYSTSIN DD DUMMY
Output of this Job is
IKJ56644I NO VALID TSO USERID, DEFAULT USER ATTRIBUTES USED READY END
But I never seen any special user definition defined for this proc.
Anybody face this issue before.
I also checked for related parmlib member BLSCECT, But I didnt find any
issues. Any clue.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to
[email protected] with the message: INFO IBM-MAIN
This e-mail transmission contains information that is confidential and may be
privileged. It is intended only for the addressee(s) named above. If you
receive this e-mail in error, please do not read, copy or disseminate it in any
manner. If you are not the intended recipient, any disclosure, copying,
distribution or use of the contents of this information is prohibited. Please
reply to the message immediately by informing the sender that the message was
misdirected. After replying, please erase it from your computer system. Your
assistance in correcting this error is appreciated.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN