I forgot to mention abut SMPE version ,

SMP/E 36.37




On Wed, Aug 13, 2014 at 12:09 PM, Mainframe Mainframe <
[email protected]> wrote:

> While running receive hold data having FIXCAT entries Job, I am getting
> below issue.
>
> //HOLDO JOB (3623),'MAINFRAME',MSGCLASS=X,CLASS=A,
> //             NOTIFY=&SYSUID,REGION=0M
> //SMPE EXEC PGM=GIMSMP
> //SMPCSI DD DSN=ZOS112.GLOBAL.CSI,DISP=SHR
> //SMPHOLD DD DISP=SHR,DSN=SMPE.FIXCAT.HOLD
> //SMPRPT DD SYSOUT=*
> //SMPOUT DD SYSOUT=*
> //SYSPRINT DD SYSOUT=*
> //SMPCNTL DD *
>     SET BDY (GLOBAL) .
>     RECEIVE HOLDDATA .
> /*
>
>
> GIM58903W    SMP/E COULD NOT PROCESS A ++HOLD FIXCAT MCS BECAUSE IT WOULD
> HAVE MADE A CHANGE TO THE GLOBAL ZONE THAT
>              CANNOT BE PROCESSED COMPLETELY BY PRIOR LEVELS OF SMP/E. USE
> THE UPGRADE COMMAND TO ALLOW SMP/E TO MAKE
>              SUCH CHANGES.
> ---------- CATEGORY(IBM.ProductInstall-RequiredService)
> GIM25201E ** THE INDICATED COMMAND IS INCOMPLETE. IT MAY BE MISSING DATA
> OR A DELIMITER, OR A PREVIOUS COMMAND MAY BE
>              MISSING A PARENTHESIS.
> GIM20501I    RECE
>
> I read about UPGRADE option in SMPE but still not able to relate with my
> issue.
>
> I think the solution of this issue can be
>
> //SMPCNTL DD *
>     SET BDY (GLOBAL) .
>     UPGRADE.
>     RECEIVE HOLDDATA .
>
> . But can anyone help me about the implication of running this UPGRADE
> command in my case and why I am facing this issue. Currently my z/Os
> version is z/Os 2.1
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,