I forgot to mention abut SMPE version , SMP/E 36.37
On Wed, Aug 13, 2014 at 12:09 PM, Mainframe Mainframe < [email protected]> wrote: > While running receive hold data having FIXCAT entries Job, I am getting > below issue. > > //HOLDO JOB (3623),'MAINFRAME',MSGCLASS=X,CLASS=A, > // NOTIFY=&SYSUID,REGION=0M > //SMPE EXEC PGM=GIMSMP > //SMPCSI DD DSN=ZOS112.GLOBAL.CSI,DISP=SHR > //SMPHOLD DD DISP=SHR,DSN=SMPE.FIXCAT.HOLD > //SMPRPT DD SYSOUT=* > //SMPOUT DD SYSOUT=* > //SYSPRINT DD SYSOUT=* > //SMPCNTL DD * > SET BDY (GLOBAL) . > RECEIVE HOLDDATA . > /* > > > GIM58903W SMP/E COULD NOT PROCESS A ++HOLD FIXCAT MCS BECAUSE IT WOULD > HAVE MADE A CHANGE TO THE GLOBAL ZONE THAT > CANNOT BE PROCESSED COMPLETELY BY PRIOR LEVELS OF SMP/E. USE > THE UPGRADE COMMAND TO ALLOW SMP/E TO MAKE > SUCH CHANGES. > ---------- CATEGORY(IBM.ProductInstall-RequiredService) > GIM25201E ** THE INDICATED COMMAND IS INCOMPLETE. IT MAY BE MISSING DATA > OR A DELIMITER, OR A PREVIOUS COMMAND MAY BE > MISSING A PARENTHESIS. > GIM20501I RECE > > I read about UPGRADE option in SMPE but still not able to relate with my > issue. > > I think the solution of this issue can be > > //SMPCNTL DD * > SET BDY (GLOBAL) . > UPGRADE. > RECEIVE HOLDDATA . > > . But can anyone help me about the implication of running this UPGRADE > command in my case and why I am facing this issue. Currently my z/Os > version is z/Os 2.1 > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN