Dave, I couldn't understand the last update. Can you please explain .



On Thu, Aug 14, 2014 at 6:48 AM, Gibney, Dave <[email protected]> wrote:

> CBPDO the latest z/OS 2.1 SMP/E into you z/OS 1.13.
> Run the UPGRADE.
> Continue on.
>
> > -----Original Message-----
> > From: IBM Mainframe Discussion List [mailto:[email protected]]
> > On Behalf Of Mainframe Mainframe
> > Sent: Wednesday, August 13, 2014 6:08 PM
> > To: [email protected]
> > Subject: Re: SMPE UPGRADE ISSUE
> >
> > Thanks Jon,
> >                   Our systems are in sysplex with different version of
> z/OS (in my
> > case its z/OS 1.13 and z/OS 2.1 ) systems. Currently I am in the process
> of
> > installing CICS 5.2 release and we have multiple CICS version in our
> shop also
> > global CSI is common for all CICS version present in systems.
> >
> > The error, I mentioned before was getting during receiving MCS and HOLD
> > data for CICS 5.2 using CBPDO order.
> > Just to cross check, I also run receive  latest FIXCAT hold data job and
> > encountered same issues.
> >
> > So, now my queries are
> >
> > 1) Why is it necessary to run UPGRADE parameter in issue.
> >
> > 2) Even if I run receive Job from z/OS 2.1  with setting boundary of
> GLobal
> > zone which is part of common global csi
> >
> > //SMPCNTL DD *
> >     SET BDY (GLOBAL) .
> >     UPGRADE.
> >     RECEIVE HOLDDATA .
> >
> > then I will not be able to use this CICS global CSI from my z/OS 1.13
> systems.
> > So, another alternative is to run this Job from z/OS 1.13 system and
> then we
> > can use in z/OS 2.1 also.
> >
> > 3) After receive, do we have to specify UPGRADE option while doing apply
> and
> > accept as well or it is only required for receive.
> >
> >
> >
> >
> >
> > On Wed, Aug 13, 2014 at 11:07 PM, Jon Perryman <[email protected]>
> > wrote:
> >
> > > Never permanently add UPGRADE to your JCL. You always want to make the
> > > decision to upgrade a zone becase it PERMANENTLY upgrades that zone.
> > > I'll discuss this in terms of z/OS release but it actually tied to the
> > > SMP/e release/PTF level (not z/OS). Let's say are running 1.12, 1.13
> > > and 2.1 z/OS and you want SMP/e to run on all 3 of those versions if
> > > possible. If you run the UPGRADE from 2.1, then this zone cannot be
> > > updated from 1.12 or 1.13. If you did the UPGRADE from 1.13, then you
> > > can't run SMP/e against this zone on your 1.12 system but can run it
> on 1.13
> > & 2.1.
> > >
> > > WARNING: Run UPGRADE from the lowest level system because you can't
> > > back it out after the change. If the receive holddata still fails,
> > > then try it on the next higher release but remember you can't use
> > > SMP/e from that system.
> > >
> > > WARNING: Permanently adding UPGRADE to your JCL could risk using
> > SMP/e
> > > from older systems. You could accidentally running the job on your
> > > newly installed 2.1 system.
> > >
> > > Jon Perryman
> > >
> > >
> > >
> > > On Wednesday, August 13, 2014 9:35 AM, Mainframe Mainframe <
> > > [email protected]> wrote:
> > >
> > >
> > > >
> > > >Thanks for reply. I am basically receiving HOLD data and getting this
> > > >issue. So, as mentioned in last update, Do I have to just update
> > > >receive JCL with
> > > >
> > > >//SMPCNTL DD *
> > > >    SET BDY (GLOBAL) .
> > > >    UPGRADE.
> > > >    RECEIVE HOLDDATA .
> > > >
> > > >above UPGRADE option and it will receive the data.But I am still not
> > > >clear
> > > >
> > >
> > > ----------------------------------------------------------------------
> > > For IBM-MAIN subscribe / signoff / archive access instructions, send
> > > email to [email protected] with the message: INFO IBM-MAIN
> > >
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions, send
> email to
> > [email protected] with the message: INFO IBM-MAIN
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to