Hi Derrick,
We are using flash express on our z/EC12's but have not changed our paging 
confiquration because of dr considerations. May not apply to you but something 
to consider.

Doug

On Wed, 3 Dec 2014 15:00:06 -0600, Derrick Haugan <[email protected]> wrote:

>We are preparing to use flash express on our EC12 based systems, and are 
>considering reconfiguring page datasets on either mod-27's or mod-54's using 1 
>local page dataset per volume, as when using the flash/SCM for paging, only 
>VIO pages will go to DASD for paging under normal circumstances. This would 
>simplify paging volume configuration. Currently on our mod27s there are 12 
>paging slots per track (run an IDCAMS/LISTCAT of the page dataset). So a mod27 
>with 30051 cyls/450,765 trk would hold 5,409,180 slots or roughly 20.6GB.
>

----------------------------------------------------------------------