On Thu, 5 Mar 2015 17:29:54 +0200, Itschak Mugzach <[email protected]> wrote:

>I am running a MPF exit that works fine from user adress spaces. In respond
>to RACF msg ICH302D, the userid assigned is +CONSOLE. The OPERCMDS profile
>is having uacc read, but racf refuses the REPLYxx,Y
>Another command issued under the same conditions (no acce)is MVS SEND
>command, this time from mstjcl00.I am trying to avoid converting to MGCRE.

- snip -

If you're wedded to the idea of staying with MGCR, what *might* work is to get 
the command out of the user space and into a system address space.  This could 
be accomplished by pre-pending "RO <cvtsname>," to your REPLY command.  
Remember to compress out any blanks for a system name that is less than eight 
characters.

No guarantees...if you try it and it works, I'd love to know (having been one 
of the original developers of the ROUTE command...).

Also, it looks like MGCR has been beefed up a bit to allow the specification of 
security information on the macro call:

http://www-01.ibm.com/support/knowledgecenter/SSLTBW_1.13.0/com.ibm.zos.r13.ieaa800/mgcr.htm

Scott Fagen
Chief Architect - z Systems and Workload Automation
CA Technologies