I am running a MPF exit that works fine from user adress spaces. In respond
to RACF msg ICH302D, the userid assigned is +CONSOLE. The OPERCMDS profile
is having uacc read, but racf refuses the REPLYxx,Y
Another command issued under the same conditions (no acce)is MVS SEND
command, this time from mstjcl00.I am trying to avoid converting to MGCRE.

Any Idea how to assign an active id to the exit, or CONSOLEID?


ICH408I USER(+CONSOLE) GROUP(*       ) NAME(???                 ) 931

  MVS.REPLY CL(OPERCMDS)

  INSUFFICIENT ACCESS AUTHORITY

  ACCESS INTENT(READ   )  ACCESS ALLOWED(NONE   )

IEE345I REPLY    AUTHORITY INVALID, FAILED BY SECURITY PRODUCT

ITschak Mugzach

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to