Charles,

I did a quick google on JSCBAUTH and long thread in 2010...very interesting
several people mentioned to SYNC and LINK to perform authorized calls
unless I misunderstood the thread.

Scott

On Monday, March 16, 2015, Scott Ford <[email protected]> wrote:

> Yes, it does.
>
> On Monday, March 16, 2015, Charles Mills <[email protected]
> <javascript:_e(%7B%7D,'cvml','[email protected]');>> wrote:
>
>> I don't really know but my logic goes like this:
>>
>> You can only turn JCSBAUTH back on if you are key 0, otherwise you will
>> S0C4. So you could set key 0, and then turn JSCBAUTH off, "do stuff," and
>> then turn it back on again -- but if you are going to run for any length of
>> time "doing stuff" in key 0 you might just as well leave JSCBAUTH on, and
>> if on the other hand you are going to go to user key, you are stuck there
>> once you turn JSCBAUTH off.
>>
>> Does that make sense?
>>
>> Charles
>>
>> -----Original Message-----
>> From: IBM Mainframe Discussion List [mailto:[email protected]] On
>> Behalf Of Scott Ford
>> Sent: Monday, March 16, 2015 3:20 PM
>> To: [email protected]
>> Subject: Re: IEBCOPYO (was: APF-authorized ...)
>>
>> I have a related question to this very informative thread. Inside a long
>> running task, i.e.; stc  can you turn off APF authorization and turn back
>> on ? Btw I have customers asked about this.
>>
>> ----------------------------------------------------------------------
>> For IBM-MAIN subscribe / signoff / archive access instructions,
>> send email to [email protected] with the message: INFO IBM-MAIN
>>
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to