Charles, I did a quick google on JSCBAUTH and long thread in 2010...very interesting several people mentioned to SYNC and LINK to perform authorized calls unless I misunderstood the thread.
Scott On Monday, March 16, 2015, Scott Ford <[email protected]> wrote: > Yes, it does. > > On Monday, March 16, 2015, Charles Mills <[email protected] > <javascript:_e(%7B%7D,'cvml','[email protected]');>> wrote: > >> I don't really know but my logic goes like this: >> >> You can only turn JCSBAUTH back on if you are key 0, otherwise you will >> S0C4. So you could set key 0, and then turn JSCBAUTH off, "do stuff," and >> then turn it back on again -- but if you are going to run for any length of >> time "doing stuff" in key 0 you might just as well leave JSCBAUTH on, and >> if on the other hand you are going to go to user key, you are stuck there >> once you turn JSCBAUTH off. >> >> Does that make sense? >> >> Charles >> >> -----Original Message----- >> From: IBM Mainframe Discussion List [mailto:[email protected]] On >> Behalf Of Scott Ford >> Sent: Monday, March 16, 2015 3:20 PM >> To: [email protected] >> Subject: Re: IEBCOPYO (was: APF-authorized ...) >> >> I have a related question to this very informative thread. Inside a long >> running task, i.e.; stc can you turn off APF authorization and turn back >> on ? Btw I have customers asked about this. >> >> ---------------------------------------------------------------------- >> For IBM-MAIN subscribe / signoff / archive access instructions, >> send email to [email protected] with the message: INFO IBM-MAIN >> > ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN