On Wed, 25 Mar 2015 16:27:33 +0000, Henn, Karl wrote:

>I do have a z/OS V2R1 *with* the error, as well as one *without* the error, 
>the difference being a couple of hundred PTFs - otherwise same HW, some 
>setup, same customization etc. 
 
>It could be that the error was not introduced with a PTF for HDZ2210. If 
>that's 
>the case, what else am I looking at then? The BCP (HBB7790)? Really? Some 
>extremely rare interdependency between components? Well, I guess I just have 
>to keep looking.

You could certainly keep looking, and I would too, if I were you. At this 
point, 
though, IBM should be able to reproduce this. They may need the output of a 
REPORT CROSSZONE between these two target zones.

-- 
Tom Marchant

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to