The earliest version of MVS (sic) that is advertised to support ARCHLVL=2 is 
z/OS 1.6

Ant. 

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf 
Of Tony Thigpen
Sent: Friday, 25 September 2015 12:14 PM
To: [email protected]
Subject: OS/390 hard wait

In a DR site, we are 'playing' with a customers OS/390 2.10 under z/VM
6.3 on a z10.

Their system was running with ARCHLVL=1, but we were having some performance 
issues, so we decided to see what would happen with ARCHLVL=2.

The initial IPL trucks along until it the console switches modes. Then the 
guest enters:

"CP disabled wait PSW 00020000 80000000 00000000 00009064"

Console:
IEA304W SYSTEM WAIT STATE CODE 80009064 DURING IEAVNPF5 INITIALIZATION

Thoughts?

--
Tony Thigpen

----------------------------------------------------------------------