Hello, We are currently receiving ADR402E message during backup of a volume.
(Long post – Please scroll down all the way).
ADR402E (001)-AUTH (26), AUTHORIZATION CHECK FAILED FOR DATA SET
SMPE.MVS.TARGET.CSI, ON VOL VOLUME MVSRES, 14-004-120, in CATALOG
CATALOG.ZOS210.MASTER
So what transpired is that we are in the preliminary stages for doing a CBPDO
upgrade from z/OS 1.12 to 2.10. We currently have MVSRES, MVSCAT & MVSDLB as
target volumes and decided to clone the system (MVS210, CAT210, DLB210). We
also created a new Master Catalog ( CATALOG.ZOS210.MASTER ) and connected it to
current master catalog ( CATALOG.ZOS120.MASTER ). We were moving a several
VSAM Datasets from MVSRES to other volumes to ensure there is no VSAM on
MVSRES.
Somehow the VVDS entries for all of VSAM datasets that are in currently
cataloged in master catalog got updated to the new master catalog (
CATALOG.ZOS210.MASTER ) on volumes where a VSAM dataset resides. I have
disconnected the new catalog ‘CATALOG CATALOG.ZOS210.MASTER’ that we created
and varied CAT210 offline). See below:
SMPE.MVS.TARGET.CSI *VSAM*
SMPE.MVS.TARGET.CSI.DATA MVSRES
SMPE.MVS.TARGET.CSI.INDEX MVSRES
LISTC ENT('SMPE.MVS.TARGET.CSI')
CLUSTER ------- SMPE.MVS.TARGET.CSI
IN-CAT --- CATALOG.ZOS120.MASTER
DATA ------- SMPE.MVS.TARGET.CSI.DATA
IN-CAT --- CATALOG.ZOS120.MASTER
INDEX ------ SMPE.MVS.TARGET.CSI.INDEX
IN-CAT --- CATALOG.ZOS120.MASTER
DIAGNOSE ICFCATALOG -
INFILE(CATDS1) -
COMPAREDD(VVDS1 )
-IDC21364I ERROR DETECTED BY DIAGNOSE:
0 ICFCAT ENTRY: SMPE.MVS.TARGET.CSI.DATA (D)
0 RECORD: SMPE.MVS.TARGET.CSI /00
0 OFFSET: X'0083'
0 REASON: 12 - CATLG AND VVDS NAMES UNEQUAL
-IDC21365I ICFCAT RECORD DISPLAY:
0 RECORD: SMPE.MVS.TARGET.CSI /00
0000000 00F40034 C3004D00 2DE2D4D7 C54BD4E5 E24BE3C1 D9C7C5E3 4BC3E2C9
40404040 *.4..C.(..SMPE.MVS.TARGET.CSI *
000020 40404040 40404040 40404040 40404040 40404040 40000014 01FFFFFF
FFFFFFFF * ...........*
000040 FF481124 5F00000F 01000005 03000000 20C40052 0019E2D4 D7C54BD4
E5E24BE3 *....^............D....SMPE.MVS.T*
000060 C1D9C7C5 E34BC3E2 C94BC4C1 E3C10000 1401FFFF FFFFFFFF FFFF0811
245F0000 *ARGET.CSI.DATA...............^..*
000080 0F010000 1E0400D4 E5E2D9C5 E2301020 0F820000 00200000 00000000
00000000 *.......MVSRES...................*
0000A0 000021C9 0053001A E2D4D7C5 4BD4E5E2 4BE3C1D9 C7C5E34B C3E2C94B
C9D5C4C5 *...I....SMPE.MVS.TARGET.CSI.INDE*
0000C0 E7000014 01FFFFFF FFFFFFFF FF081124 5F00000F 0100001E 0400D4E5
E2D9C5E2 *X...............^.........MVSRES*
0000E0 3010200F 82000000 20000000 00000000 00000000
*.................... *
-IDC21365I VVDS RECORD DISPLAY:
0 RECORD: X'00002145'
0000000 02350062 E9000000 000019E2 D4D7C54B D4E5E24B E3C1D9C7 C5E34BC3
E2C94BC4 *....Z......SMPE.MVS.TARGET.CSI.D*
000020 C1E3C100 14E2D4D7 C54BD4E5 E24BE3C1 D9C7C5E3 4BC3E2C9 0015C3C1
E3C1D3D6 *ATA..SMPE.MVS.TARGET.CSI..CATALO*
000040 C74BE9D6 E2F2F1F0 4BD4C1E2 E3C5D914 E2D4D7C5 4BD4E5E2 4BE3C1D9
C7C5E34B *G.ZOS210.MASTER.SMPE.MVS.TARGET.*
000060 C3E2C900 00552140 60000000 50000000 27000004 C0038F40 0003A5C0
00000000 *CSI.... -...&.......{.. ...{....*
000080 180000FF FFFFFFFF FFFFFF00 00000008 00000000 00000000 00000000
00000000 *................................*
0000A0 00000000 00000000 00000249 00003C80 00000000 00000000 00006260
80006000 *...........................-..-.*
0000C0 00000000 18070000 5A000600 00000000 00200000 00008F00 00000000
00000000 *........!.......................*
0000E0 00000008 00000000 000000CF A5E76679 849B4400 00000C00 145AF400
019EAB00 *.............X...........!4.....*
000100 018A7A00 00000001 4A39DB01 37200000 00027900 00001900 028C8101
1A23800C *..:.....¢.......................*
000120 0274C000 038F4000 03A5C000 00002000 0006000F 40000F00 00000000
00000000 *..{... ...{......... ...........*
000140 00000000 F000010B B300000B D9000E02 49000000 0001B6BF FF000220
2F000020 *....0.......R...................*
000160 32000E00 3C01B6C0 0001E3BF FF000320 33000020 36000E00 3C01E3C0
000210BF *.......{..T...............T{....*
000180 FF000420 37000020 3A000E00 3C0210C0 00023DBF FF000520 3B000020
3E000E00 *...............{................*
0001A0 3C023DC0 00026ABF FF000620 3F000020 42000E00 3C026AC0 000297BF
FF000720 *...{...................{........*
1IDCAMS SYSTEM SERVICES TIME:
08:53:56 10/24/15 PAGE 2
00001C0 43000020 46000E00 3C0297C0 0002C4BF FF000820 47000020 4A000E00
3C02C4C0 *...........{..D.........¢.....D{*
0001E0 0002F1BF FF000920 4B000020 4E000E00 3C02F1C0 00031EBF FF000A26
DA000026 *..1.........+.....1{............*
000200 DD000E00 3C031EC0 00034BBF FF000B26 DE000026 E1000E00 3C034BC0
000378BF *.......{...................{....*
000220 FF000C26 E2000026 E5000E00 3C0378C0 0003A5BF FF
*....S...V......{..... *
-IDC21364I ERROR DETECTED BY DIAGNOSE:
0 ICFCAT ENTRY: SMPE.MVS.TARGET.CSI.INDEX (I)
0 RECORD: SMPE.MVS.TARGET.CSI /00
0 OFFSET: X'00D6'
0 REASON: 12 - CATLG AND VVDS NAMES UNEQUAL
-IDC21365I ICFCAT RECORD DISPLAY:
0 RECORD: SMPE.MVS.TARGET.CSI /00
0IDC01371I RECORD DISPLAY SUPPRESSED, ALREADY DUMPED.
-IDC21365I VVDS RECORD DISPLAY:
0 RECORD: X'0000237A'
0000000 01960063 E9080000 00001AE2 D4D7C54B D4E5E24B E3C1D9C7 C5E34BC3
E2C94BC9 *....Z......SMPE.MVS.TARGET.CSI.I*
000020 D5C4C5E7 0014E2D4 D7C54BD4 E5E24BE3 C1D9C7C5 E34BC3E2 C90015C3
C1E3C1D3 *NDEX..SMPE.MVS.TARGET.CSI..CATAL*
000040 D6C74BE9 D6E2F2F1 F04BD4C1 E2E3C5D9 14E2D4D7 C54BD4E5 E24BE3C1
D9C7C5E3 *OG.ZOS210.MASTER.SMPE.MVS.TARGET*
000060 4BC3E2C9 00005521 40600000 00000000 00040000 01800005 20000005
40000000 *.CSI.... -.................. ...*
000080 00000000 FFFFFFFF FFFFFFFF 00000000 08000000 00000000 00000000
00000000 *................................*
0000A0 00000000 00000000 00000000 00000000 00000000 00000000 00000062
60000060 *............................-..-*
0000C0 00090000 00180000 000C0000 00000000 00001000 00000FF9 00002000
00000000 *.......................9........*
0000E0 00000000 08000000 00000000 CFA5E766 79849B44 00020004 00000052
00000000 *..............X.................*
000100 00000000 00000464 00000000 00002000 00000019 00000000 000023E7
007A2380 *...........................X.:..*
000120 04000000 00000520 00000540 00000010 00000C00 0140000F 00000000
00000000 *........... ......... ..........*
000140 00000000 00500001 00590001 00590004 00040000 00000002 FFFF0002
0059000E *.....&..........................*
000160 0059000E 00010003 00000003 BFFF0003 1F1A000B 1F1A000B 00010003
C0000004 *............................{...*
000180 7FFF0004 1F1A000C 1F1A000C 00010004 80000005 3FFF
*"..................... *
-IDC21363I THE FOLLOWING ENTRIES HAD ERRORS:
- SMPE.MVS.TARGET.CSI.DATA (D) - REASON CODE: 12
0 SMPE.MVS.TARGET.CSI.INDEX (I) - REASON CODE: 12
0IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 8
1IDCAMS SYSTEM SERVICES TIME:
08:53:56 10/24/15 PAGE 3
0
0IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 8
EXAMINE NAME(CATALOG.ZOS120.MASTER) NOINDEXTEST DATATEST
IDC01701I DATATEST BEGINS
IDC01709I DATATEST COMPLETE - NO ERRORS DETECTED
IDC01708I 205 CONTROL INTERVALS ENCOUNTERED
IDC01710I DATA COMPONENT CONTAINS 4779 RECORDS
IDC01711I DATA COMPONENT CONTAINS 1 DELETED CONTROL INTERVALS
IDC01712I MAXIMUM LENGTH DATA RECORD CONTAINS 1979 BYTES
IDC01722I 93 PERCENT FREE SPACE
IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0
IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 0
DIAG VVDS INFILE(VVDS1) COMPAREDD(CATDS1)
IDC11373I THE FOLLOWING COMPARE ELEMENTS WERE NOT ENCOUNTERED:
CATDS1
IDC11367I THE FOLLOWING VVDS REFERENCED CATALOGS WERE NOT ENCOUNTERED:
CATALOG.ZOS120.MASTER
CATALOG.TSOUSER
IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 4
IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 4
EXAMINE NAME(CATALOG.ZOS120.MASTER) INDEXTEST NODATATEST
0IDC2917I NO RACF PROFILE ON STGADMIN.IDC.EXAMINE.DATASET
- IDC01700I INDEXTEST BEGINS
IDC11773I 205 KEYS PROCESSED ON INDEX LEVEL 1, AVERAGE KEY LENGTH
IDC11773I 2 KEYS PROCESSED ON INDEX LEVEL 2, AVERAGE KEY LENGTH
IDC11774I CURRENT INDEX CISIZE IS 3584, RECOMMENDED MINIMUM INDEX CISIZE IS 3
0IDC01724I INDEXTEST COMPLETE - NO ERRORS DETECTED
0IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0
0IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 0
Let me know if I can provide additional information and somehow we have to
change the catalog entries from (CATALOG.ZOS210.MASTER) to
(CATALOG.ZOS120.MASTER) in VVDS / VVR record in order to catalog and VVDS to be
in Sync.
Thanks for any help in advance.
Sonny Gupta
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN