Caveat:  I'm a daily digester so list responses are always delayed... (plus 
someone's probably beat me to it. *grin*)

Few more items to scratch of the possibilities list:

1)  Verify you are *not* using 'ACTIVE' as the CDS name in the ISMF panels.  
You *cannot* alter the 'ACTIVE' CDS.  You must use the 'real' name ie. from the 
ListCat, then activate that CDS to make it 'ACTIVE'.

2)  use the Volume panel (=ISMF.2.1) [1] to verify the error message.  You can 
define volSer's to SMS that do not physically exist (yet). [2]  Using '*' for 
SG name will search them all.  Re-do the search with both 'ACTIVE' and 'real' 
SCDS name.  To use the Volume list in Storage Groups (=ISMF.6), you must search 
*each* SG by name. (or list them all with sub-option 1 and ListVol against each 
of them; arduous)

3)  I also couldn't find DGTSG079 in the Knowledge Centre. [3]  Did you re-type 
the error?  Most (*all*?) IBM messages have a trailing 'level' indicator such 
as 'I' for informational.

4)  Did you "Check the Volume Failures Panel to review the volsers you 
specified." as recommended & what was the result?

[1]  DGTDVVA1 VOLUME SELECTION ENTRY PANEL
Specify Source of the New List  . . 2 (SMS)

  Type of Volume List . . . 3 
  Volume Serial Number  . . BOB*
  Acquire Physical Data . . Y
  Acquire Space Data  . . . Y
  Storage Group Name  . . . * 
  CDS Name . . . . . . . 'ACTIVE'

[2]  *all* my pools have 50+ spare volSer's defined so I don't have to activate 
a new SMS configuration just to ICKDSF a new pack to the pool.  You can also 
remove a pack without removing the volSer from the SG.  Over the course of 
months, I'm always adding/removing volumes using ICKSDF in response to 
application use.

[3]  
http://www-01.ibm.com/support/knowledgecenter/SSLTBW_2.1.0/com.ibm.zos.v2r1/en/homepage.html

-------->  signature = 8 lines follows  <--------
Neil Duffee, Joe Sysprog, uOttawa, Ottawa, Ont, Canada
telephone:1 613 562 5800 x4585                  fax:1 613 562 5161
mailto:NDuffee of uOttawa.ca     http:/ /aix1.uOttawa.ca/ ~nduffee
“How *do* you plan for something like that?”  Guardian Bob, Reboot
“For every action, there is an equal and opposite criticism.”
“Systems Programming: Guilty, until proven innocent”  John Norgauer 2004
"Schrodinger's backup: The condition of any backup is unknown until a restore 
is attempted."  John McKown 2015

-----Original Message-----
From: Brent Snyder [mailto:[email protected]] 
Sent: March 1, 2016 10:02
Subject: Re: IBM-MAIN Digest - 28 Feb 2016 to 29 Feb 2016 (#2016-60)

Dave, Lizette and Linda -

The SCDS is defined with REUSE option.
Also:
SHROPTNS(3,3) RECOVERY UNIQUE NOERASE NOWRITECHK NONORDERED RESUSE NONSPANNED

LISTC ENT(scds) ALL shows
ALLOCATION
  SPACE-TYPE------CYLINDER     HI-A-RBA--------66355200
  SPACE-PRI-------------90     HI-U-RBA--------31571968
  SPACE-SEC--------------0

Just tried to add a new volser (DASD), did not receive any IGD messages in the 
SYSLOG.

HELP-----------------------------ISMF MESSAGE------------------------------HELP
COMMAND ===>

   MESSAGE NUMBER:  DGTSG079  (could not find explanation of this error message)

   SHORT MESSAGE:   NO VOLUMES DEFINED

   LONG MESSAGE:    None of the specified volumes were DEFINED


   EXPLANATION:
     The requested function DEFINE was not successfully completed for any
     of the volumes specified.  In general, if DEFINE fails it means the
     volumes have already been defined in the specified CDS.
     It could also be that the SCDS is full.

   SUGGESTED ACTION:
     Check the Volume Failures Panel to review the volsers you specified.
     If you believe the operation should have been successful, retry it.
     If the problem still occurs, please contact your systems programmer
     for assistance.

I checked the VOLUME option, the volser is not defined to any storage groups.

I've been on this account since November, this is the first time I have needed 
to add volumes to any of the storage groups.

----------------------------------------------------------------------