>You are correct that the ZIIP dispatcher is not as sophisticated as the 
>regular dispatcher.


I dare to contradict, not intending to question you expertise. It is my 
understanding that there is only one dispatcher in MVS. It handles work on the 
CP WUQ as well as work on the zIIP WUQ. The reason for the wait time mechanism 
is explained in Init&Tuning Ref, IEAOPTxx.


--