On Mon, 14 Nov 2016 13:12:06 -0500, Farley, Peter x23353 wrote:
>Trying to find where in the Fine Manuals the limitation of PDSE to one volume
>is documented. For some unknown reason I AssUMed that PDSE had solved the
>single-volume limitation for libraries and I am being told I am wrong (which
>is likely).
>
>I just need to find the actual documentation of this limitation.
>
Another one; I don't know where it might be documented:
With a classic PDS with, e.g., RECFM=FB,LRECL=80 I can override to LRECL=40
and each record is split into two. With PDSE I get:
IEC141I 013-EC,IGG0191A,RECFM,STEP,SYSUT1,...
I don't know whether you call this a limitation; it's at least a behavioral
difference.