A job step containing:

//  EXPORT SYMLIST=*
//  SET TEST='This is the value of the substituted string.'
//STEP1    EXEC  PGM=IEBGENER
//SYSUT1    DD  *,SYMBOLS=JCLONLY,DCB=LRECL=222
    This is a test of symbol use in instream data sets.  Test here: &TEST
//* This is a test of symbol use in instream data sets.  Test here: This is the 
value of the substituted string.

Fails with SYSPRINT containing:

1DATA SET UTILITY - GENERATE                                                    
       PAGE 0001
-IEB352I WARNING: ONE OR MORE OF THE OUTPUT DCB PARMS COPIED FROM INPUT
 IEB351I I/O ERROR ,JCLSYM  ,STEP1   ,JES ,D,SYSUT1  ,READ  ,WRONG LEN 
RECRD,**************,BSAM

Against which component should I submit the SR?  I doubt that it's Utilities;
perhaps JES2 or DfSMS?

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@listserv.ua.edu with the message: INFO IBM-MAIN

Reply via email to