Sorry, DDDEF DDnames are the same between releases, and the apply of HADB610
contains ++DELETES for the old releases.
HADB400 DELETED FUNCTION
HADB420 DELETED FUNCTION
HADB510 DELETED FUNCTION
HADB520 DELETED FUNCTION
HADB610 APPLIED FUNCTION HADB610 IFREQ UI43370
I was able to fix the problem however with some simple UCLIN.
UCLIN .
DEL SYSMOD(MCOB001).
ENDUCL .
SET BOUNDARY (MVSCBD).
UCLIN .
DEL SYSMOD(MCOB001).
ENDUCL .
After which I was able to receive, and apply. So life is good.
_________________________________________________________________
Dave Jousma
Manager Mainframe Engineering, Assistant Vice President
[email protected]
1830 East Paris, Grand Rapids, MIĀ 49546 MD RSCB2H
p 616.653.8429
f 616.653.2717
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Allan Staller
Sent: Tuesday, May 09, 2017 10:49 AM
To: [email protected]
Subject: Re: BUILDMCS fallout
Different FMID's. IIRC, different DDDEFs. Should not be any conflict with both
compilers in the same zone.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Jousma, David
Sent: Tuesday, May 9, 2017 9:34 AM
To: [email protected]
Subject: BUILDMCS fallout
All,
Maybe a SMPE guru can help me. We are starting to work on conversion project
to move from Enterprise COBOL 4.2 to 6.1 and as part of the installation, I did
a BUILDMCS on the FMID's for V4.2 so that I could move it into its own set of
zones, so that I could install V6.1 into my z/OS zones. The BUILDMCS, and
follow-on's to receive and apply into the new zones went fine. However, my
usermod for setting default options(MCOB001) somehow got SUP'd by FMID for
COBOL. I've been able to overcome this by coming up with a new usermod name,
and having it PRE(MCOB001), but if at all possible, I'd like to get this fixed.
The usermod wasn't ACCEPTED in its prior zones, so not exactly sure how this
happened.
>From the target zone, and oddly, shows the same for the COBOL DLIB zone as
>well. Is there a way to remove this relationship? MCOB001 is not applied.
Primary Command: FIND
Entry Type: SYSMOD Zone Name: MVSCBT
Entry Name: MCOB001 Zone Type: TARGET
Description:
Type: Status:
FMID: SUPBY HADB420
Date/Time:
_________________________________________________________________
Dave Jousma
Manager Mainframe Engineering, Assistant Vice President [email protected]
1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f 616.653.2717
This e-mail transmission contains information that is confidential and may be
privileged.
It is intended only for the addressee(s) named above. If you receive this
e-mail in error, please do not read, copy or disseminate it in any manner. If
you are not the intended recipient, any disclosure, copying, distribution or
use of the contents of this information is prohibited. Please reply to the
message immediately by informing the sender that the message was misdirected.
After replying, please erase it from your computer system. Your assistance in
correcting this error is appreciated.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
----------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended
for the named recipient(s) only.
E-mail transmission is not guaranteed to be secure or error-free as information
could be intercepted, corrupted, lost, destroyed, arrive late or incomplete, or
may contain viruses in transmission. The e mail and its contents (with or
without referred errors) shall therefore not attach any liability on the
originator or HCL or its affiliates.
Views or opinions, if any, presented in this email are solely those of the
author and may not necessarily reflect the views or opinions of HCL or its
affiliates. Any form of reproduction, dissemination, copying, disclosure,
modification, distribution and / or publication of this message without the
prior written consent of authorized representative of HCL is strictly
prohibited. If you have received this email in error please delete it and
notify the sender immediately.
Before opening any email and/or attachments, please check them for viruses and
other defects.
----------------------------------------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to
[email protected] with the message: INFO IBM-MAIN
This e-mail transmission contains information that is confidential and may be
privileged. It is intended only for the addressee(s) named above. If you
receive this e-mail in error, please do not read, copy or disseminate it in any
manner. If you are not the intended recipient, any disclosure, copying,
distribution or use of the contents of this information is prohibited. Please
reply to the message immediately by informing the sender that the message was
misdirected. After replying, please erase it from your computer system. Your
assistance in correcting this error is appreciated.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN