R.S. wrote:
[...]
List -
Just curious if the EAV volumes can be used for SYSRES volumes or if
there are any concerns with using them for SYSRES volumes?

If they can be used for SYSRES, any considerations with using them?



Just looking for advise.

IMHO there are few things to consider:

1. EAV consist of EAS (upper space) and traditional "track-addressable"
space. SYSRES and probably everything else can be placed below the line
of 65520 cyl, because it is regular "legacy" 3390-54 volume.

True.

2. What can be placed "above the line" (that means in EAS)? That's the
question. I would not try to place there any of operational datasets
like RACF db, logrec archive, SYS1.MANx, etc. UNLESS it is clearly
documented.

Right. Not sure we have documented this well, though, so if you find some missing things, please submit RCFs.

 From the other hand - SYSRES is NOT the place for operational datasets!

I certainly agree!

This is a room for target libraries. I would not worry about non-LPA and
non-LNKLST libraries and non-IPL_LNKLST (dynamically added) libraries.
And most non-executable (RECFM=U) libraries.

For this and #3, see the list I posted in response to Lizette's original post.

3. What about ZFS and HFS? I would check it again, but IMHO all of them
can be placed in EAS.

4. What about ServerPac Installation Dialog? Does it support EAV yet?

It does not. It likely will never do so. We are moving in a different direction, with z/OSMF Software Management as our installer in a few years, I hope.


--
John Eells
IBM Poughkeepsie
[email protected]

----------------------------------------------------------------------