Sorry, I should've said z13.

Martin Packer,
zChampion, Principal Systems Investigator,
Worldwide Cloud & Systems Performance, IBM

+44-7802-245-584

email: [email protected]

Twitter / Facebook IDs: MartinPacker

Blog: 
https://www.ibm.com/developerworks/mydeveloperworks/blogs/MartinPacker

Podcast Series (With Marna Walle): https://developer.ibm.com/tv/mpt/    or 
  
https://itunes.apple.com/gb/podcast/mainframe-performance-topics/id1127943573?mt=2



From:   Martin Packer <[email protected]>
To:     [email protected]
Date:   26/10/2017 09:33
Subject:        Re: z14 FICON and (old) Brocade switch
Sent by:        IBM Mainframe Discussion List <[email protected]>



I had a customer recently with old switches between z14 and DS8870. Both 
ends were rated higher than the switches and demonstrably - from 74-8 - 
the links had been negotiated down.

That might or might not matter to you.

Long ago I had a situation where customer was running PPRC at high speed 
across town over low-speed fabric. That caused errors and, IIRC, outages.

That probably DOES matter to you.

But, as always, finance might override that.

Martin Packer,
zChampion, Principal Systems Investigator,
Worldwide Cloud & Systems Performance, IBM

+44-7802-245-584

email: [email protected]

Twitter / Facebook IDs: MartinPacker

Blog: 
https://www.ibm.com/developerworks/mydeveloperworks/blogs/MartinPacker

Podcast Series (With Marna Walle): https://developer.ibm.com/tv/mpt/    or 

 
https://urldefense.proofpoint.com/v2/url?u=https-3A__itunes.apple.com_gb_podcast_mainframe-2Dperformance-2Dtopics_id1127943573-3Fmt-3D2&d=DwIFBA&c=jf_iaSHvJObTbx-siA1ZOg&r=BsPGKdq7-Vl8MW2-WOWZjlZ0NwmcFSpQCLphNznBSDQ&m=76hc8NkIHhBlfUtAsX7AWtLrx3hr-uYlnBVSsN-WpEk&s=GrcAXo-2p9yQyKBKvdryd3Zki5P690Dv8WbJnYEJkBw&e=




From:   "Alan(GMAIL)Watthey" <[email protected]>
To:     [email protected]
Date:   26/10/2017 09:27
Subject:        Re: z14 FICON and (old) Brocade switch
Sent by:        IBM Mainframe Discussion List <[email protected]>



What are they gossipping about?  Certainly the new Multihop feature won't
work on old SAN Switches. That's where you have three switches in the 
path.
Ficon has only supported either a single hop or one hop (cascading) up 
until
now.

Also, old switches might not support dynamic routing.  Old switches may 
only
support static switching (port routing on really old switches and the
slightly better device routing on less old switches).

Old switches won't support 16Gbps either so they'll negotiate down to 8 or
lower.  That'll depend upon fibre type and distance as well.


-----Original Message-----
From: R.S. [mailto:[email protected]] 
Sent: 25 October 2017 2:38 pm
Subject: z14 FICON and (old) Brocade switch

I heard some gossips about z14 with new FICON Express16S+ and old FICON 
switches. Is it real issue or just FUD to sell new SAN devices?

I have some 5100 switches (8Gbps) and I don't like to replace it just 
because it "wasn't certified".

Any clue?

-- 
Radoslaw Skorupka
Lodz, Poland




======================================================================


        --
 TreœÌ tej wiadomoœci mo¿e zawieraÌ informacje prawnie chronione 
Banku
przeznaczone wy³¹cznie do u¿ytku s³u¿bowego adresata. Odbiorc¹ mo¿e 
byĂŚ
jedynie jej adresat z wy³¹czeniem dostêpu osób trzecich. Je¿eli nie 
jesteÂś
adresatem niniejszej wiadomoÂści lub pracownikiem upowaÂżnionym do jej
przekazania adresatowi, informujemy, Âże jej rozpowszechnianie, 
kopiowanie,
rozprowadzanie lub inne dziaÂłanie o podobnym charakterze jest prawnie
zabronione i mo¿e byÌ karalne. Je¿eli otrzyma³eœ tê wiadomoœÌ 
omyÂłkowo,
prosimy niezwÂłocznie zawiadomiĂŚ nadawcĂŞ wysyÂłajÂąc odpowiedÂź oraz 
trwale
usun¹Ì tê wiadomoœÌ w³¹czaj¹c w to wszelkie jej kopie wydrukowane 
lub
zapisane na dysku.

 This e-mail may contain legally privileged information of the Bank and is
intended solely for business use of the addressee. This e-mail may only be
received by the addressee and may not be disclosed to any third parties. 
If
you are not the intended addressee of this e-mail or the employee 
authorized
to forward it to the addressee, be advised that any dissemination, 
copying,
distribution or any other similar activity is legally prohibited and may 
be
punishable. If you received this e-mail by mistake please advise the 
sender
immediately by using the reply facility in your e-mail software and delete
permanently this e-mail including any copies of it either printed or saved
to hard drive.

 mBank S.A. z siedzibÂą w Warszawie, ul. Senatorska 18, 00-950 Warszawa,
www.mBank.pl, e-mail: [email protected]Âąd Rejonowy dla m. st. Warszawy 
XII
WydziaÂł Gospodarczy Krajowego Rejestru SÂądowego, nr rejestru 
przedsiĂŞbiorcĂłw
KRS 0000025237, NIP: 526-021-50-88. WedÂług stanu na dzieĂą 01.01.2016 r.
kapitaÂł zakÂładowy mBanku S.A. (w caÂłoÂści wpÂłacony) wynosi 168.955.696
zÂłotych.
 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN




Unless stated otherwise above:
IBM United Kingdom Limited - Registered in England and Wales with number 
741598. 
Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN




Unless stated otherwise above:
IBM United Kingdom Limited - Registered in England and Wales with number 
741598. 
Registered office: PO Box 41, North Harbour, Portsmouth, Hampshire PO6 3AU

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to