On Wed, Nov 1, 2017 at 10:19 AM, PINION, RICHARD W. < [email protected]> wrote:
> Would someone be so kind as to give me an example of calling IKJEFT1B > from an assembler program. The CALL macro I am using is passing control > to IKJEFT1B, but I receive "IKJ56600I UNRECOVERABLE COMMAND SYSTEM > ERROR". I'm assuming the parameters I am passing are incorrect. And, no > my need is not to invoke it directly from JCL via //STEP010 EXEC > PGM=IKJEFT1B. > FIRST TENNESSEE > > there has been some recent discussion about how IKJEFT01 and it's aliases (IKJEFT1A & IKJEFT1B) should _not_ be invoked by anything other that EXEC PGM= or via the "TMP session manager". Of course, you are free to do whatever you need to do to "get the job done". I am curious if, instead, you could use the "TSO Environment Services" (IKJTSOEV) as documented at: https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.1.0/com.ibm.zos.v2r1.ikjb700/whenuse.htm Also, just because I'm curious, what are you trying to accomplish (at a high level, details not needed). -- I have a theory that it's impossible to prove anything, but I can't prove it. Maranatha! <>< John McKown ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN