Change 35.212 Support for SMF 30 User Key CSA Audit Enhancements adds
VMAC30 new SMF30_RAXFLAGS to TYPE30_1, TYPE30_V, TYPE30_4 and
Sep 28, 2017 the TYPE30_5 datasets. This code change has been in MXG
Feb 28, 2018 35.09 and later, but this change text replaced previous
"Reserved Change" on Feb 28, 2018. This field was added
by APAR OA53355, but will only be needed thru z/OS 2.3,
as User Key Common Storage usage support ends there.
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of Jousma, David
Sent: Tuesday, April 24, 2018 1:47 PM
To: [email protected]
Subject: OA53355 - USERKEY COMMON MIGRATION SUPPORT
So, has anyone written a SAS/MXG program to read through these SMF30 records
yet, that they would care to share? Seems to be the easiest method to run
through the daily data to determine who is using USER Key common? I see
the slip noted in the APAR, and I could go that route, but still have to
look through GTF data it seems.
I know I have one long running home-grown system task for sure using it, but
what I do not know if there are any short lived usage. We are already
working on retiring the home-grown system task.
SA38-0667-XX z/OS MVS System Management Facilities (SMF)
Add the following new SMF Type 30 record fields in the
Storage and Paging Section:
Offsets Name Length Format...
178 B2 SMF30_RAXFLAGS 1 binary...
Description
Bit Meaning
0 When SMF30_USERKEYCOMMONAUDITENABLED is on,
auditing of user key common storage usage attempts
enabled for this step/job.
SMF30_USERKEYCSAUSAGE, SMF30_USERKEYCADSUSAGE and
SMF30_USERKEYCHANGKEYUSAGE are only applicable when
this flag is on.
1 When SMF30_USERKEYCSAUSAGE is on, attempts were made
to obtain user key CSA storage for this step/job.
This bit is only valid when
SMF30_USERKEYCOMMONAUDITENABLED is on.
Once this bit is set on for an interval record, this
bit will also be set on for all subsequent interval
records for this step.
Once this bit is set on for a job interval or step-end
record, this bit will also be set on for step-total
and job-end records.
2 When SMF30_USERKEYCADSUSAGE is on, attempts were made
to create a user key CADS for this step/job.
This bit is only valid when
SMF30_USERKEYCOMMONAUDITENABLED is on.
Once this bit is set on for an interval record, this
bit will also be set on for all subsequent interval
records for this step.
Once this bit is set on for a job interval or step-end
record, this bit will also be set on for step-total
and job-end records.
3 When SMF30_USERKEYCHANGKEYUSAGE is on, attempts were
made to change the key of common ESQA storage to a user
key (via CHANGKEY) for this step/job.
This bit is only valid when
SMF30_USERKEYCOMMONAUDITENABLED is on.
Once this bit is set on for an interval record, this
bit will also be set on for all subsequent interval
records for this step.
Once this bit is set on for a job interval or step-end
record, this bit will also be set on for step-total
and job-end records.
_________________________________________________________________
Dave Jousma
Manager Mainframe Engineering, Assistant Vice President [email protected]
1830 East Paris, Grand Rapids, MI 49546 MD RSCB2H p 616.653.8429 f
616.653.2717
This e-mail transmission contains information that is confidential and may
be privileged.
It is intended only for the addressee(s) named above. If you receive this
e-mail in error, please do not read, copy or disseminate it in any manner.
If you are not the intended recipient, any disclosure, copying, distribution
or use of the contents of this information is prohibited. Please reply to
the message immediately by informing the sender that the message was
misdirected. After replying, please erase it from your computer system. Your
assistance in correcting this error is appreciated.
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email
to [email protected] with the message: INFO IBM-MAIN
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN