SDSF issue. "ENQ * *" shows everything.
Format: ENQ (major-name) (system-name)
major-name is the enqueue major name to process including
* (any string of characters) or % (any single character).
The default is SYSDSN.
system-name is the MVS system name, up to 8 characters
including * (any string of characters) or % (any single
character). The default is the local system name.
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Richards, Robert B.
Sent: Friday, July 13, 2018 10:44 AM
To: [email protected]
Subject: (External):Re: Friday Strangeness ISRDDN ENQ ?
Jim,
What about the SDSF's ENQ? SYSNAME * only shows the system I am logged onto
I tried changing to SYSNAME "lparx" and the display did not change?
Feel free to not reply while I RTFM. :-)
Bob
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Jim Mulder
Sent: Friday, July 13, 2018 1:36 PM
To: [email protected]
Subject: Re: Friday Strangeness ISRDDN ENQ ?
This message suggests that ISRDDN is using GQSCAN with XSYS=NO or ISGQUERY
with GATHERFROM=SYSTEM
I don't know if there is any way to tell ISRDDN to use XSYS=YES or
GATHERFROM=SYSPLEX.
Jim Mulder z/OS Diagnosis, Design, Development, Test IBM Corp.
Poughkeepsie NY
> When I use the command TSO ISRDDN ENQ 'SYS1.PROCLIB' I get this message:
>
> ISRDD020 This system is running with SETGRS MODE=STAR. ENQ information
will
> not be collected from othe
r systems. As a result, ENQ displays may not
> reflect all of the ENQs which are known to GRS.
>
> Is there a way to enhance ISRDDN to get all the ENQ's?
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN