So...."Once it happens, they can not get the program to ever run correctly
again, even after re-compiling."

And yet they deleted a program and problem solved?

Isn't this going to happen again on the next compile?

You implied it wasn't just one program but something that the contractor
was doing....



On Tue, Jul 24, 2018 at 2:12 AM, Tony Thigpen <[email protected]> wrote:

> I have a site with a bunch of old RPG programs. Lately, it seems that
> sometimes the get the following. Once it happens, they can not get the
> program to ever run correctly again, even after re-compiling.
>
> IEC020I 001-4,HSR003B,STEP0017,STYWRK,1818,HKYP05,
> IEC020I PROD.HKY.WORK.HSR003B.WK1.S050
> IEC020I DCB EROPT=ABE OR AN INVALID CODE, AND/OR NO SYNAD EXIT SPECIFIED
>
> We have a contractor working on 'performance issues' with this machine,
> and I am wondering if he has changed something. The customer is just now
> telling us, but they say it happens every few weeks to a different program.
> Usually, the programs are simple, so they are just rewriting them in
> Natural.
>
> Fridays problem program was very simple:
> FSTYWRK  UP  F9000 300            DISK40
> ISTYWRK  NS  01
> I                                      100 100 ALTCLS
> C           ALTCLS    COMP ' '                  25
> OSTYWRK  D        01
> O                                   71 '0'
> O                 25                72 '09'
>
> //STEP0017 EXEC PGM=HAO07E,PARM='DATE=$WEDATE',
> //         COND=(3,LT)
> //STYWRK   DD DSN=PROD.HKY.WORK.HSR003B.WK1.S050,
> //         DISP=(OLD,KEEP,KEEP)
> //SYSUDUMP DD SYSOUT=*
> //SYSPRINT DD SYSOUT=*
> /*
>
> Any suggestions? Questions?
>
> --
> Tony Thigpen
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN
>



-- 
Wayne V. Bickerdike

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN