>the regular LX is easier as I only need I register to PC

That strikes me as the wrong attitude. This is authorized code. You should 
also be considering what is best for the system (and the rest of the users 
within the system), not only what is easiest.

>If my started task goes down and I restart it the virtual address in 
private of the PC routine would be different isn’t that an issue

It's not an issue, it's a fact. When you restart, you are still connecting 
an entry table to an LX, whether it is an LX that is newly reserved or is 
an LX that is being re-connected-to. You still need to build the entry 
table, so should be doing so as part of the restart process, using the 
addresses you find within your restarted space.