By way of update, after studying everyone's suggestions, I ran the job with
this DD:
//TAPEIN DD UNIT=(TAPECR,,DEFER),
// LABEL=(EXPDT=98000),
// VOL=SER=(nnnnnn),
// DISP=(OLD,KEEP)
and got pretty much the same result:
IEF403I TAPEANAL - STARTED - TIME=14.37.42
IEC501A M uuuu, nnnnnn,BLP,,TAPEANAL,FATAR
EDG4020I VOLUME nnnnnn REJECTED BY INSTALLATION REJECT DEFINITIONS
EDG4006E VOLUME nnnnnn ON uuuu REJECTED FOR USE BY TAPEANAL, FATAR, TAPEIN,
OPEN REQUEST FAILED BY DFSMSrmm
IEC502E R uuuu,, ,,TAPEANAL,FATAR
IEC145I 413-08,IFG0194K,TAPEANAL,FATAR,TAPEIN,uuuu,, 015
SYS18353.T143742.RA000.TAPEANAL.R0161338
IEA995I SYMPTOM DUMP OUTPUT 016
SYSTEM COMPLETION CODE=413 REASON CODE=00000008
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office ⇐=== NEW
[email protected]
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf
Of Allan Staller
Sent: Thursday, December 20, 2018 5:48 AM
To: [email protected]
Subject: (External):Re: Dancing around RMM
IIRC, there is some RACF work needed to support BLP.
-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of
Jesse 1 Robinson
Sent: Wednesday, December 19, 2018 3:54 PM
To: [email protected]
Subject: Dancing around RMM
We want to discard some very old tapes after making sure there's nothing of
value on them. When we run Innovation FATAR to analyze them, the jobs fail with
messages like those below using JCL like this:
//TAPEIN DD UNIT=TAPECR,LABEL=(,BLP),
// DISP=OLD,VOL=SER=(nnnnnn)
There's a whole slew of STGADMIN profiles in FACILITY class that allow the user
to get around 'irregularities', but we can't seem to find one that would allow
this usage. The tapes are not defined to RMM. We just want to know what's on
the tapes before the trash truck pulls out of the loading dock.
EDG4025I VOLUME nnnnnn REJECTED. READING OF SCRATCH VOLUMES OR VOLUMES OBTAINED
WITH GETVOLUME IS NOT PERMITTED EDG4006E VOLUME nnnnnn ON uuuu REJECTED FOR USE
BY FATARAN1, FATAR, TAPEIN, OPEN REQUEST FAILED BY DFSMSrmm
IEC502E R uuuu,, ,,FATARAN1,FATAR
IEC145I 413-08,IFG0194K,FATARAN1,FATAR,TAPEIN,uuuu,,
SYS18352.T164910.RA000.FATARAN1.R0140502
.
.
J.O.Skip Robinson
Southern California Edison Company
Electric Dragon Team Paddler
SHARE MVS Program Co-Manager
323-715-0595 Mobile
626-543-6132 Office <===== NEW
[email protected]<mailto:[email protected]>
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN