In the past we were able to reconnect to a TSO session when our VPN disconnected via the use of Gilbert St Flour's IKJEFLN2. The implementation of LOGONHERE made this exit unnecessary. However, now we can no longer reconnect to a session when the VPN disconnects, due to a network issue or it just goes down, even though we have an S for RECONNECT in the USS display. Now we immediately get the following messages:
IKT100I USERID userid CANCELED DUE TO UNCONDITIONAL LOGOFF IKT122I IPADDR..PORT nnn.nnn.nnn.nnn..50569 IEF450I userid proc procstep - ABEND=S622 U0000 REASON=00000000 Both LOGONHERE and RECONLIM are defaulted (YES and 20 respectively). I am able to switch a TSO session to another TN3270 session without a problem but not when the VPN connection goes down (after it comes back up well within the 20 minutes, of course). All I can think is that some TCPIP parameter like DISCONNECTABLE or INACTIVE was not carried forward when we upgraded our z/OS even though the defaults for these parameters seem fine. I logon using the DNS name of one of our z/OS systems. I know I could logon to the system using a VM DIAL command but when I do that, I lose the the use of the ATTN on the keyboard to interrupt a long running REXX or program. Any help would be appreciated but I need a fix not a workaround. j ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN