I typically apply maintenance to my base target zone which has an associated 
DLIB zone which is never IPLed from.   I have 3 SYSRES volumes per environment 
(TECH, DEV, PROD-A, PROD-B) for a total of 12 SYSRES volumes.   I have a 
cloning process that besides building the entire sysres, also does a full SMPE 
ZONECOPY to match it, and is connected to the common Global.   At any time, I 
have a complete and in-tact SMPE environment to match every SYSRES.    This has 
been helpful for IBM support wanting to know a PTF Level of a particular 
module, to applying the PTF in a pinch(very rare), etc.

_________________________________________________________________
Dave Jousma
Mainframe Engineering, Assistant Vice President
[email protected]
1830 East Paris, Grand Rapids, MIĀ  49546 MD RSCB2H
p 616.653.8429
f 616.653.2717


-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Bill Giannelli
Sent: Wednesday, March 13, 2019 1:31 PM
To: [email protected]
Subject: SMPe "rollout" of maintenance

**CAUTION EXTERNAL EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

When I obtain maintenance for an RSU (e.i. for Db2 RSU1902).
I receive and apply, then implement first in one of our 2 sand boxes, leaving 
our 2nd sand box at our prior maintenance level.
My question is, before I have rolled out the new maintenance, what if I need a 
one off PTF for the prior maintenance?
Should 2 CSIs be kept? One for new maintenance and a second one for a prior 
maintenance level.
Thanks
Bill

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN **CAUTION EXTERNAL 
EMAIL**

**DO NOT open attachments or click on links from unknown senders or unexpected 
emails**

This e-mail transmission contains information that is confidential and may be 
privileged.   It is intended only for the addressee(s) named above. If you 
receive this e-mail in error, please do not read, copy or disseminate it in any 
manner. If you are not the intended recipient, any disclosure, copying, 
distribution or use of the contents of this information is prohibited. Please 
reply to the message immediately by informing the sender that the message was 
misdirected. After replying, please erase it from your computer system. Your 
assistance in correcting this error is appreciated.


----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to