Structures are setup, but since datasharing isn't yet activated they're not 
allocated.

Mark Jacobs


Sent from ProtonMail, Swiss-based encrypted email.

GPG Public Key - 
https://api.protonmail.ch/pks/lookup?op=get&[email protected]

‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐
On Friday, May 24, 2019 6:42 AM, Elardus Engelbrecht 
<[email protected]> wrote:

> Mark Jacobs wrote:
>
> > Since there's more activity here than in the RACF mailing list, thought I'd 
> > ask here first. I changed the flag byte in the RACF dataset names table to 
> > enable sysplex communications today, and ipled the first system with the 
> > changed table. Even though it's not talking to another system yet via XCF, 
> > I had thought the RVARY LIST command issued on that system would have told 
> > me that it's enabled for sysplex communications. I've verified that this 
> > system is using the updated load module.
>
> Are your structures setup and activated?
>
> Do a D XCF,STRUCTURE to see them.
>
> ... also issue D XCF,STRUCTURE,STRNAME=<RACF structure>
>
> Check these output:
>
> .....
>
> STATUS: ALLOCATED
> .....
>
> CONNECTION NAME ID VERSION SYSNAME JOBNAME ASID STATE
>
> IRRP001@???? 02 00020058 ???? RACFDS 0017 ACTIVE
>
> If you don't see it, check your setup of the CF structure.
>
> > rvary list
> > ICH15013I ACCF DATABASE STATUS:
> > ACTIVE USE NUM VOLUME DATASET
> >
> > YES PRIM 1 SYS001 SYS1.PROD.RACF
> > YES BACK 1 SYS011 SYS1.PROD.RACF.BACKUP
> > ICH15020I RVARY COMMAND HAS FINISHED PROCESSING.
>
> > Here's what I set in the table;
>
> > ICHRDSNT CSECT
> > DC AL1(1) INDICATES ONE RACF DATA SET
> > DC CL44'SYS1.PROD.RACF' PRIMARY RACF DS NAME
> > DC CL44'SYS1.PROD.RACF.BACKUP' BACKUP RACF DS NAME
> > DC AL1(255) # OF RESIDENT DATA BLOCKS
> >
> > -          DC    B'01234567'                  BIT COUNT
> >           DC    B'10001000'                  SYSPLEX, NON DATASHARING
> >           END
> >
> >
>
> AL1(1) is easy ... ;-)
>
> > Any ideas?
>
> I have first X'C8' - 1100 1000 during all the initial setup of CF and the 
> structures.
>
> Then IPL, etc. where you get SysPlex and NON DATASHARING.
>
> Then after verifying all is Ok and you can get DATASHARING working, then I 
> code in X'CC' - 1100 1100 (and then IPL at a convenient time)
>
> If all is working you should get this:
>
> MEMBER <sid> IS SYSPLEX COMMUNICATIONS ENABLED & IN DATA SHARING MODE.
>
> Ok, above is perhaps too elaborate, but I was just very cautious and have 
> practised on a sandbox SysPlex.
>
> Good luck!
>
> Groete / Greetings
> Elardus Engelbrecht
>
> ----------------------------------------------------------------------------------------------------------------------------------------------------------------
>
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: INFO IBM-MAIN

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to