Structures are setup, but since datasharing isn't yet activated they're not allocated.
Mark Jacobs Sent from ProtonMail, Swiss-based encrypted email. GPG Public Key - https://api.protonmail.ch/pks/lookup?op=get&[email protected] ‐‐‐‐‐‐‐ Original Message ‐‐‐‐‐‐‐ On Friday, May 24, 2019 6:42 AM, Elardus Engelbrecht <[email protected]> wrote: > Mark Jacobs wrote: > > > Since there's more activity here than in the RACF mailing list, thought I'd > > ask here first. I changed the flag byte in the RACF dataset names table to > > enable sysplex communications today, and ipled the first system with the > > changed table. Even though it's not talking to another system yet via XCF, > > I had thought the RVARY LIST command issued on that system would have told > > me that it's enabled for sysplex communications. I've verified that this > > system is using the updated load module. > > Are your structures setup and activated? > > Do a D XCF,STRUCTURE to see them. > > ... also issue D XCF,STRUCTURE,STRNAME=<RACF structure> > > Check these output: > > ..... > > STATUS: ALLOCATED > ..... > > CONNECTION NAME ID VERSION SYSNAME JOBNAME ASID STATE > > IRRP001@???? 02 00020058 ???? RACFDS 0017 ACTIVE > > If you don't see it, check your setup of the CF structure. > > > rvary list > > ICH15013I ACCF DATABASE STATUS: > > ACTIVE USE NUM VOLUME DATASET > > > > YES PRIM 1 SYS001 SYS1.PROD.RACF > > YES BACK 1 SYS011 SYS1.PROD.RACF.BACKUP > > ICH15020I RVARY COMMAND HAS FINISHED PROCESSING. > > > Here's what I set in the table; > > > ICHRDSNT CSECT > > DC AL1(1) INDICATES ONE RACF DATA SET > > DC CL44'SYS1.PROD.RACF' PRIMARY RACF DS NAME > > DC CL44'SYS1.PROD.RACF.BACKUP' BACKUP RACF DS NAME > > DC AL1(255) # OF RESIDENT DATA BLOCKS > > > > - DC B'01234567' BIT COUNT > > DC B'10001000' SYSPLEX, NON DATASHARING > > END > > > > > > AL1(1) is easy ... ;-) > > > Any ideas? > > I have first X'C8' - 1100 1000 during all the initial setup of CF and the > structures. > > Then IPL, etc. where you get SysPlex and NON DATASHARING. > > Then after verifying all is Ok and you can get DATASHARING working, then I > code in X'CC' - 1100 1100 (and then IPL at a convenient time) > > If all is working you should get this: > > MEMBER <sid> IS SYSPLEX COMMUNICATIONS ENABLED & IN DATA SHARING MODE. > > Ok, above is perhaps too elaborate, but I was just very cautious and have > practised on a sandbox SysPlex. > > Good luck! > > Groete / Greetings > Elardus Engelbrecht > > ---------------------------------------------------------------------------------------------------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: INFO IBM-MAIN ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: INFO IBM-MAIN