I just went through this. There are 2 "levels" of RACF sharing
SYSPLEX Data Sharing (CF required) and SYSPLEX Communications (no CF required).

SYSPLEX Data Sharing is b'10001100'  (x'8C')
SYSPLEX Communication is b'10001000' (x'88').

What you have set up is SYSPLEX Communication. RACF will not be using the CF in 
this mode.
I believe the bits are described in the data areas manual for ICHRDSNT.

HTH,

-----Original Message-----
From: IBM Mainframe Discussion List <[email protected]> On Behalf Of 
Mark Jacobs
Sent: Thursday, May 23, 2019 5:38 PM
To: [email protected]
Subject: ICHRDSNT Table. RACF in sysplex communications mode

Since there's more activity here than in the RACF mailing list, thought I'd ask 
here first. I changed the flag byte in the RACF dataset names table to enable 
sysplex communications today, and ipled the first system with the changed 
table. Even though it's not talking to another system yet via XCF, I had 
thought the RVARY LIST command issued on that system would have told me that 
it's enabled for sysplex communications. I've verified that this system is 
using the updated load module.

rvary list
ICH15013I RACF DATABASE STATUS:
ACTIVE USE  NUM VOLUME   DATASET
------ ---  --- ------   -------
  YES   PRIM   1 SYS001   SYS1.PROD.RACF
  YES   BACK   1 SYS011   SYS1.PROD.RACF.BACKUP
ICH15020I RVARY COMMAND HAS FINISHED PROCESSING.
READY

Here's what I set in the table;

ICHRDSNT CSECT
         DC    AL1(1)                       INDICATES ONE RACF DATA SET
         DC    CL44'SYS1.PROD.RACF'         PRIMARY RACF DS NAME
         DC    CL44'SYS1.PROD.RACF.BACKUP'  BACKUP  RACF DS NAME
         DC    AL1(255)                     # OF RESIDENT DATA BLOCKS
*        DC    B'01234567'                  BIT COUNT
         DC    B'10001000'                  SYSPLEX, NON DATASHARING
         END

Any ideas?

Sent from 
[ProtonMail](https://apc01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fprotonmail.com&amp;data=02%7C01%7Callan.staller%40HCL.COM%7C93996759aae54386463508d6dfcf5db6%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C0%7C636942479084451598&amp;sdata=2L65kcSXzRAvREzt6rUY2bgAWxqdHRQ%2F4Ln%2FphzAytM%3D&amp;reserved=0),
 Swiss-based encrypted email.

GPG Public Key - 
https://apc01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fapi.protonmail.ch%2Fpks%2Flookup%3Fop%3Dget%26search%3Dmarkjacobs%40protonmail.com&amp;data=02%7C01%7Callan.staller%40HCL.COM%7C93996759aae54386463508d6dfcf5db6%7C189de737c93a4f5a8b686f4ca9941912%7C0%7C0%7C636942479084451598&amp;sdata=%2FHIUk2TQxS0YeB15GLXH%2BkeBg6%2FAJTzJyp%2FjKrzEJ0s%3D&amp;reserved=0

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions, send email to 
[email protected] with the message: INFO IBM-MAIN
::DISCLAIMER::
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only. E-mail transmission is not guaranteed to be 
secure or error-free as information could be intercepted, corrupted, lost, 
destroyed, arrive late or incomplete, or may contain viruses in transmission. 
The e mail and its contents (with or without referred errors) shall therefore 
not attach any liability on the originator or HCL or its affiliates. Views or 
opinions, if any, presented in this email are solely those of the author and 
may not necessarily reflect the views or opinions of HCL or its affiliates. Any 
form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of this message without the prior written 
consent of authorized representative of HCL is strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any email and/or attachments, please check them for 
viruses and other defects.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN

Reply via email to