On Thu, 30 May 2019 09:59:14 -0400, Tony Thigpen <[email protected]> wrote:
>Maybe you have a 'better way' to use NPF. Could you give me an example
>of what you are doing?
>
So JES2 never selects output for that printer? You don't ever get $HASP150 ?
What I do is all output for network printers goes to Class C. Different
destination for each different remote printer such as OPSPRT, SYSPRT, XRXPRT.
Different forms use different Options member.
My printer is defined like this:
PRT3 CLASS=C,
MODE=FSS,
FSS=TCPFSS,
FCB=STD8,
CKPTPAGE=100,
START=YES,
WS=(W,R,Q,PRM,LIM/F,UCS,FCB,P),
ROUTECDE=(*PRT)
I'm going from fuzzy memory here, as I set this up a number of years ago and
our environment is pretty static, haven't had to revisit it much.
Dana
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN