On Thursday, 08/30/2007 at 10:11 EDT, [EMAIL PROTECTED] wrote: > 1) We are defining the control units as device type 2105, whereas you > are using 3990.
z/VM doesn't care about the UNIT= parameter in your IOCP. On z/VM 3.1, the control unit will operate as a 3990. > 2) You have a "PCHID" parameter on your CHPID statements that out IOCP > does not have. PCHIDs are not present on MP2K, so that's ok. You need to talk to Hitachi. Alan Altmark z/VM Development IBM Endicott