Hello all!
I am in a bit of a bind. We just acquired a new 
(used) printer, Infoprint 4000/IS1, with ESCON 
connection. Until now we used a 3900 with bus/tag 
on a CVC channel, with a converter (9043?).

I need to set up definitions for it, but unfortunately 
I have been out on medical leave, and am going *tonight* 
to be hospitalized for surgery followed by several 
weeks of recuperation. I got home from the hospital 
last night for a break, and logged in from home to try
to set things up. (Sorry about the personal stuff, but 
it explains my rush...)

Following the 'lockstep method' I did these operations:
1) updated my IOCP file, and successfully compiled it.
2) made dynamic changes with CP commnds

I wanted to write to the IOCDS at this point, but my 
contact at work had left early, so there was still a 
write-protect on it.
This morning he turned off the write-protect on A3, 
and I continued:

3) wrote the new IOCP to IOCDS A3.
4) *tried* to SET IOCDS_ACTIVE A3.

Step 4 failed. :-(
HCPZQY6812E SET IOCDS_ACTIVE COMMAND FAILED WITH RETURN CODE 
0088

So as I understand this message, the token in the CSS 
(which I guess is the result of the dynamic changes I 
made yesterday) does not match the token in the IOCDS 
(which I just stored).

What exactly does this mean? 
a) that the IOCP really does not match what I did dynamically?
b) the token in the CSS is dated yesterday, but the IOCDS is
from today? 
c) some other problem?

And what can I do now?  

All help will be much appreciated!
Shimon

Reply via email to