Hello all! I am in a bit of a bind. We just acquired a new (used) printer, Infoprint 4000/IS1, with ESCON connection. Until now we used a 3900 with bus/tag on a CVC channel, with a converter (9043?).
I need to set up definitions for it, but unfortunately I have been out on medical leave, and am going *tonight* to be hospitalized for surgery followed by several weeks of recuperation. I got home from the hospital last night for a break, and logged in from home to try to set things up. (Sorry about the personal stuff, but it explains my rush...) Following the 'lockstep method' I did these operations: 1) updated my IOCP file, and successfully compiled it. 2) made dynamic changes with CP commnds I wanted to write to the IOCDS at this point, but my contact at work had left early, so there was still a write-protect on it. This morning he turned off the write-protect on A3, and I continued: 3) wrote the new IOCP to IOCDS A3. 4) *tried* to SET IOCDS_ACTIVE A3. Step 4 failed. :-( HCPZQY6812E SET IOCDS_ACTIVE COMMAND FAILED WITH RETURN CODE 0088 So as I understand this message, the token in the CSS (which I guess is the result of the dynamic changes I made yesterday) does not match the token in the IOCDS (which I just stored). What exactly does this mean? a) that the IOCP really does not match what I did dynamically? b) the token in the CSS is dated yesterday, but the IOCDS is from today? c) some other problem? And what can I do now? All help will be much appreciated! Shimon