The CUADD on the CNTLUNIT must match up to the control unit number
defined by the CE in the device. In my case, since other systems were
defined to the DASD first, my control units are 1C and 1D. z9 running
z/VM 5.3.0.
CHPID PATH=(CSS(0),30),PCHID=100,TYPE=FC,PART=(LP1)
CHPID PATH=(CSS(0),31),PCHID=110,TYPE=FC,PART=(LP1)
CHPID PATH=(CSS(0),32),PCHID=101,TYPE=FC,PART=(LP1)
CHPID PATH=(CSS(0),33),PCHID=111,TYPE=FC,PART=(LP1)
CTL30 CNTLUNIT CUNUMBR=3000,PATH=(30,31,32,33),UNITADD=((00,256)), *
CUADD=1C,UNIT=2105
CTL31 CNTLUNIT CUNUMBR=3100,PATH=(30,31,32,33),UNITADD=((00,32)), *
CUADD=1D,UNIT=2105
IODEVICE ADDRESS=(3000,256),CUNUMBR=(3000), *
UNIT=3390
IODEVICE ADDRESS=(3100,32),CUNUMBR=(3100), *
UNIT=3390
-----Original Message-----
From: The IBM z/VM Operating System [mailto:[EMAIL PROTECTED] On
Behalf Of daver++
Sent: June 25, 2008 08:48
To: [email protected]
Subject: 2105-800 FICON IOCP problem
Hi, we are in the process of migrating from an ESCON attached 2105-F20
to a FICON attached 2105-800. This is my first FICON IOCP, and I am
having some issues. We are on a z/800 running VSE (3.1.2) under VM
(5.2). The 2105-800 is attached directly to the z/800, no director. Here
is the IOCP I am trying:
CHPID PATH=(1E),TYPE=FC
CHPID PATH=(1F),TYPE=FC
CHPID PATH=(20),TYPE=FC
CHPID PATH=(21),TYPE=FC
...
CNTLUNIT CUNUMBR=0034,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=0
CNTLUNIT CUNUMBR=0035,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=1
CNTLUNIT CUNUMBR=0036,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=2
CNTLUNIT CUNUMBR=0037,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=3
CNTLUNIT CUNUMBR=0038,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=4
CNTLUNIT CUNUMBR=0039,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=5
CNTLUNIT CUNUMBR=0040,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=6
CNTLUNIT CUNUMBR=0041,PATH=(1E,1F,20,21), *
UNIT=2105,UNITADD=((00,96)),CUADD=7
IODEVICE ADDRESS=(500,96),CUNUMBR=(0034),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(560,96),CUNUMBR=(0035),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(5C0,96),CUNUMBR=(0036),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(620,96),CUNUMBR=(0037),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(680,96),CUNUMBR=(0038),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(6E0,96),CUNUMBR=(0039),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(740,96),CUNUMBR=(0040),UNIT=3390,STADET=Y,UNITADD=00
IODEVICE ADDRESS=(7A0,96),CUNUMBR=(0041),UNIT=3390,STADET=Y,UNITADD=00
I've also tried it with four byte LINKs:
CNTLUNIT CUNUMBR=0034,PATH=(1E,1F,20,21),LINK=(****,****,****,****),...
and two byte LINKs:
CNTLUNIT CUNUMBR=0034,PATH=(1E,1F,20,21),LINK=(**,**,**,**),...
VM is telling me error 05F0 when I try to bring up the CHPID,
configuration error. The z800 is telling me the channel is reserved due
to configuration error, but I can't seem to figure out what the
configuration error is.
Does anything jump out at anyone that I am completely missing here?
Thanks.
The information transmitted is intended only for the person or entity to which
it is addressed and may contain confidential and/or privileged material. Any
review retransmission dissemination or other use of or taking any action in
reliance upon this information by persons or entities other than the intended
recipient or delegate is strictly prohibited. If you received this in error
please contact the sender and delete the material from any computer. The
integrity and security of this message cannot be guaranteed on the Internet.
The sender accepts no liability for the content of this e-mail or for the
consequences of any actions taken on the basis of information provided. The
recipient should check this e-mail and any attachments for the presence of
viruses. The sender accepts no liability for any damage caused by any virus
transmitted by this e-mail. This disclaimer is property of the TTC and must
not be altered or circumvented in any manner.