1010 is "cannot find console" - Did you bring up the "Integrated 3270 
console" on the HMC and specify "SYSG" as the (load) parm?

> I changed the system config adding page packs and such and might have 
had a finger check!
 Did you run CPSYNTAX before the SHUTDOWN RIEPL?  I alwasy "acc 193 g" (to 
pick up the CPSYNTAX command), then "cpsyntax system config f" (or 
whichever disk CF1 is accessed as) before ReIPLing.

"Mike MacIsaac" <[EMAIL PROTECTED]>   (845) 433-7061



"Martin, Terry R. (CMS/CTR) (CTR)" <[EMAIL PROTECTED]> 
Sent by: The IBM z/VM Operating System <[email protected]>
09/12/2008 04:23 PM
Please respond to
The IBM z/VM Operating System


To
[email protected]
cc

Subject
[IBMVM] WAIT STATE






Hi 
 
I am trying to bring up a new VM LPAR and I am receiving a DISABLED WAIT 
STATE CODE: 1010.
 
Any ideas?
 
Thank You,
 
Terry Martin
Lockheed Martin - Information Technology
z/OS & z/VM Systems - Performance and Tuning
Cell - 443 632-4191
Work - 410 786-0386
[EMAIL PROTECTED]
 

Reply via email to