Dave, 802 went on without a hitch here... Pat -----Original Message----- From: The IBM z/VM Operating System [mailto:[email protected]] On Behalf Of Dave Jones Sent: Monday, January 05, 2009 11:38 AM To: [email protected] Subject: z/VM 5.4 RSU 802 problem
Hi, gang. I've downloaded the latest RSU 802 for z.VM 5.4; the SERVICE step runs without problem. After some testing, I did the PUT2PROD step, but I'm receiving the following errors during the segment processing step: ---------------------------------------------------------------------------- ST:VMFP2P2760I PUT2PROD processing started for segment DOSINST ST:AUTO LOGON *** BLDSEG USERS = 15 ST:BLDSEG : z/VM V5.4.0 2008-08-24 11:16 ST:BLDSEG : Ready; T=0.01/0.02 13:53:17 ST:BLDSEG : VMFBLD2760I VMFBLD processing started ST:BLDSEG : VMFBLD1851I Reading build lists ST:BLDSEG : VMFBLD2182I Identifying new build requirements ST:BLDSEG : VMFBLD2182I No new build requirements identified ST:BLDSEG : VMFBLD1851I (1 of 1) VMFBDSEG processing SEGBLIST EXC00000 ST:D, target is BUILD ST:BLDSEG : 51D (D) ST:BLDSEG : VMFBDS2115I Validating segment DOSINST ST:BLDSEG : VMFSET2204I Linking MAINT 3C4 as 3C4 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03C4 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3C4 3C4 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3C2 as 3C2 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03C2 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3C2 3C2 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3D2 as 3D2 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03D2 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3D2 3D2 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3A6 as 3A6 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03A6 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3A6 3A6 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3A4 as 3A4 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03A4 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3A4 3A4 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3A2 as 3A2 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03A2 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3A2 3A2 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 3B2 as 3B2 with the link mode MR ST:BLDSEG : HCPLNM107E MAINT 03B2 not linked; not in CP directory ST:BLDSEG : VMFSET1965E The command, CP LINK MAINT 3B2 3B2 MR, failed ST:with return code 107 ST:BLDSEG : VMFSET2204I Linking MAINT 490 as 490 with the link mode MR ST:BLDSEG : VMFSET2204I Linking MAINT 493 as 493 with the link mode MR ST:BLDSEG : HCPLNM102E DASD 0493 forced R/O; R/W by MAINT ST:BLDSEG : VMFBDS1965E The command, VMFSETUP, failed with return code ST:100 when issued with ST:BLDSEG : the argument(s): ZVM BLDDOS (LINK LOG NONE ST:NOCONS RETAIN A B D S Y ST:BLDSEG : VMFBLD1851E (1 of 1) VMFBDSEG completed with return code ST:100. Some objects were ST:BLDSEG : not built ST:BLDSEG : VMFBLD2180I There are 4 build requirements remaining ST:BLDSEG : VMFBLD2760I VMFBLD processing completed unsuccessfully ST:BLDSEG : Ready(00008); T=12.27/13.25 13:53:31 ST:BLDSEG : CONNECT= 00:00:15 VIRTCPU= 000:12.65 TOTCPU= 000:14.93 ST:BLDSEG : LOGOFF AT 13:53:31 CST SATURDAY 12/27/08 BY MAINT ST:USER DSC LOGOFF AS BLDSEG USERS = 14 FORCED BY MAINT ST:BLDSEG : RDR FILE 0012 SENT FROM BLDSEG CON WAS 0012 RECS 0041 CPY ST:001 T NOHOLD NOKEEP ST:DASD 019D LINKED R/W; R/O BY 12 USERS SV:VMFP2P1965E The command, CP SEND BLDSEG EXEC VMFBLD PPF SEGBLD ESASEGS SV: SEGBLIST DOSINST.SEGMENT LINK (SERVICED NOLOG, failed with SV: return code 8 ST:VMFP2P2760I PUT2PROD processing completed unsuccessfully for SEGMENTS ST:VMFP2P2760I PUT2PROD processing completed unsuccessfully ------------------------------------------------------------------ It appears that PUT2PROD is attempting to access minidisks that don't exist; they don't exist because I installed 5.4 using the SFS option, instead of the minidisk one, i.e., on the INSTPLAN exec, I selected option 'F' for all of the installable components. Anybody see what I'm doing wrong here? Thanks and have a good one. -- DJ V/Soft z/VM and mainframe Linux expertise, training, consulting, and software development www.vsoft-software.com