On 03/21/2017 09:10 AM, Ashis Biswas wrote:
I have a problem of conflicting FEFF calculation for
tris(acetate-O)arsenic [As(OCOCH3)3] (TAA) and tris(phenyl thio)arsenic
[As(SC6H5)3] (TPA); respective cif and atom input files are attached. In
Artemis, when I import TAA after TPA, the paths obtained for TAA from
FEFF calculation are different compared to the scenario when I import
and calculate the path for TAA at first. The problem is similar in both
computers with Windows 7 home premium 64 bit operating system and 0.9.24
version of Demeter and Windows 7 professional 32 bit operating system
and 0.9.25 version of Demeter.
I have even tried a scenario, where I discarded both FEFF objects after
getting inconsistent results for TAA and then imported TAA at first
without restarting Artemis and I got wrong paths again, indicating
software can remember from last calculation. Any explanation for this
problem will be deeply appreciated.
I don't observe this using the input data you supplied and the recipes
you describe.
I have no idea what TAA is supposed to look like, but the atoms list and
the path list are identical regardless of the order in which I import
your two files.
You will need to find a way to demonstrate to me better how to see what
you are seeing. Perhaps if you saved Artemis project files that I could
then open on my own computer....
B
--
Bruce Ravel ------------------------------------ bra...@bnl.gov
National Institute of Standards and Technology
Synchrotron Science Group at NSLS-II
Building 743, Room 114
Upton NY, 11973
Homepage: http://bruceravel.github.io/home/
Software: https://github.com/bruceravel
Demeter: http://bruceravel.github.io/demeter/
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit