On Thu, 12 Jan 2012 23:21:10 +0100 Vincent Vanackere <[email protected]> wrote: > I'm happy to report that this patch indeed fixes the issue for me (tested > both on linus' master and drm-intel-next). > Note that I had to apply it by hand (the patch was mangled by your mailer > ?), therefore I'm resending your fix as an attachment in case other people > are interested. > > Many thanks for the quick fix !
Great, thanks for testing. Your fixed up patch was missing one line
though, can you re-test with it added?
After the:
temp &= ~PORT_TRANS_SEL_MASK;
you need to also add a:
temp |= PORT_TRANS_SEL_CPT(pipe);
in case you end up running the LVDS off of transcoder B.
Thanks,
--
Jesse Barnes, Intel Open Source Technology Center
signature.asc
Description: PGP signature
_______________________________________________ Intel-gfx mailing list [email protected] http://lists.freedesktop.org/mailman/listinfo/intel-gfx