Matt Roper <[email protected]> writes:
> On Mon, Feb 02, 2026 at 06:43:19PM -0300, Gustavo Sousa wrote:
>> From: Shekhar Chauhan <[email protected]>
>>
>> Add platform definition along with device IDs for NVL-P.
>
> Not sure if you wanted to add bspec references to this one like you had
> for the Xe3p_LPG descriptor, but the flags you have here look correct to
> me for now and the PCI IDs look correct so,
>
> Reviewed-by: Matt Roper <[email protected]>
Thanks!
I'll send v2 with the list of fields and Bspec references. I'm
copying/pasting them here as well, just in case you can spot any errors
before I post v2:
.dma_mask_size (Bspec 74198)
.has_cached_pt (Bspec 71582)
.has_display (Bspec 74196)
.has_flat_ccs (Bspec 65255)
.has_page_reclaim_hw_assist (Bspec 73451)
.max_gt_per_tile (Bspec 74196)
.va_bits (Bspec 74198)
.vm_max_level (Bspec 59507)
--
Gustavo Sousa