On Thu, Feb 26, 2015 at 06:19:41PM +0530, [email protected] wrote:
> From: Akash Goel <[email protected]>
> 
> Prior to SKL, the time period programmed in Up/Down EI & Up/Down
> threshold registers was in units of 1.28 micro seconds. But for
> SKL, the units have changed (1.333 micro seconds).
> Have generalized the implementation of gen6_set_rps_thresholds function,
> by removing the hard coding done in it as per 1.28 micro seconds.
> 
> v2: Renamed the local variables & removed superfluous comments (Chris)
> 
> Signed-off-by: Akash Goel <[email protected]>
Reviewed-by: Chris Wilson <[email protected]>
-Chris

-- 
Chris Wilson, Intel Open Source Technology Centre
_______________________________________________
Intel-gfx mailing list
[email protected]
http://lists.freedesktop.org/mailman/listinfo/intel-gfx

Reply via email to