I'm pretty sure this will work, though installing an update later may require you to remove the symlink & re-create it again.

I know you can specify an alternate settings directory for intermapperd in the launchd .plist file (the man page has more details on that) - don't know if that affects IMDC as well or if it would live through upgrades though. (Incidentally the same .plist is the one to edit to make intermapperd start up as someone other than the user who installed it :)


The IMDC database is in postgres if I remember correctly, so you can move that with tablespaces (or make sure to initdb your postgres cluster on the volume you want to use - probably the better choice if your system volume is a SSD)

-MG

On Oct 20, 2009, at 18:33, Paul Carlson <[email protected]> wrote:

Chris,

Just out of curiosity did you try creating the Symlink afterwards? Maybe the application doesn't really care but the installer does.

Just a thought.

Paul - Guam

On Oct 21, 2009, at 5:20 AM, Chris Kawchuk wrote:

Hi All,

Installing Intermapper on a nice shiny new Snow Leopard 10.6 Xserve 2009 Server with an SSD drive and a nice 1TB RAID of Hard disk.

Naturally, I'd like Intermapper's heavily-changing Data/Logs/ Intermapper DataCentre IMDC stuff to reside on my /Volumes/RAID Partition; instead of the "boot" drive

( i.e. IM is normally installed in /usr/local/....im-stuff-goes- here...)

So, Being someone unix clueful, I created a Symlink for /usr/local/ to point instead to /Volumes/RAID/IntermapperStuff/

However, the Installer now kacks on this ("Hey Operator - It appears that /usr/ or /usr/local is a symlink - no dice on install - contact support").

So, I am following the Dialog's advice and contacting support - and I think my question here might be somewhat obvious.

->>>

How do I get Intermapper and/or Intermapper IMDC to nicely "live" on another drive in my system?

->>>

(Note: the internal 128Gb SSD Drive I want to leave completely for the OS stuff - and any logs/mail/IMdatabase/things-that-change-alot I wish to keep on the RAID - as it's easier to rebuild a RAID if it fails instead of popping off the li of the Xserve to replace the SSD drive).

Suggestions/Comments/Key lime pies w/whipped topping welcome.

- Chris.

____________________________________________________________________
List archives:http://www.mail-archive.com/intermapper-talk %40list.dartware.com/
To unsubscribe: send email to: [email protected]


Paul Carlson
VP Network Administration
Guam Cablevision, LLC.

Phone: +1 671 969-4102



____________________________________________________________________
List archives:http://www.mail-archive.com/intermapper-talk %40list.dartware.com/
To unsubscribe: send email to: [email protected]

____________________________________________________________________
List archives: http://www.mail-archive.com/intermapper-talk%40list.dartware.com/
To unsubscribe: send email to: [email protected]

Reply via email to