Arkadiusz Miskiewicz wrote: > Reset your BMC (ipmitool mc ....) Reset works fine, thanks.
The lan access still does not work but this is another story. It may be a newtork problem. Is the MAC address for default GW mandatory? ----------------------------------------------------------------------------- # ipmitool lan print 1 Set in Progress : Set Complete Auth Type Support : NONE MD2 MD5 PASSWORD Auth Type Enable : Callback : : User : MD5 : Operator : MD5 : Admin : MD5 PASSWORD : OEM : MD5 IP Address Source : Static Address IP Address : 85.x.x.x Subnet Mask : 255.255.255.0 MAC Address : 00:30:48:30:77:c5 SNMP Community String : public IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10 BMC ARP Control : ARP Responses Disabled, Gratuitous ARP Disabled Gratituous ARP Intrvl : 2.0 seconds Default Gateway IP : 85.x.x.x Default Gateway MAC : 00:00:00:00:00:00 ^^^^^^^^^^^^^^^^^? ----------------------------------------------------------------------------- # ipmitool channel info 1 Channel 0x1 info: Channel Medium Type : 802.3 LAN Channel Protocol Type : IPMB-1.0 Session Support : multi-session Active Session Count : 0 Protocol Vendor ID : 7154 Volatile(active) Settings Alerting : enabled Per-message Auth : enabled User Level Auth : enabled Access Mode : always available Non-Volatile Settings Alerting : enabled Per-message Auth : enabled User Level Auth : enabled Access Mode : always available ----------------------------------------------------------------------------- # ipmitool user list 1 ID Name Callin Link Auth IPMI Msg Channel Priv Limit 2 ADMIN true true true ADMINISTRATOR 3 _ipmi_1 true true true ADMINISTRATOR ----------------------------------------------------------------------------- # ipmitool -I lan -H 85.x.x.x -U ADMIN -E chassis status Unable to read password from environment Password: Error: Unable to establish LAN session ipmi_lan_send_cmd failed to open intf Error sending Chassis Status command ----------------------------------------------------------------------------- # ipmitool -I lanplus -H 85.x.x.x -U ADMIN -E chassis status Unable to read password from environment Password: Error: Unable to establish IPMI v2 / RMCP+ session Error sending Chassis Status command ----------------------------------------------------------------------------- Supermicro IPMIView2 does not detect it either. Regards, Daniel Toma ------------------------------------------------------------------------- Using Tomcat but need to do more? Need to support web services, security? Get stuff done quickly with pre-integrated technology to make your job easier Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642 _______________________________________________ Ipmitool-devel mailing list Ipmitool-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/ipmitool-devel