Arkadiusz Miskiewicz wrote:
> Reset your BMC (ipmitool mc ....)
Reset works fine, thanks.
The lan access still does not work but this is another story. It may be a
newtork problem. Is the MAC address for default GW mandatory?
-----------------------------------------------------------------------------
# ipmitool lan print 1
Set in Progress : Set Complete
Auth Type Support : NONE MD2 MD5 PASSWORD
Auth Type Enable : Callback :
: User : MD5
: Operator : MD5
: Admin : MD5 PASSWORD
: OEM : MD5
IP Address Source : Static Address
IP Address : 85.x.x.x
Subnet Mask : 255.255.255.0
MAC Address : 00:30:48:30:77:c5
SNMP Community String : public
IP Header : TTL=0x40 Flags=0x40 Precedence=0x00 TOS=0x10
BMC ARP Control : ARP Responses Disabled, Gratuitous ARP Disabled
Gratituous ARP Intrvl : 2.0 seconds
Default Gateway IP : 85.x.x.x
Default Gateway MAC : 00:00:00:00:00:00
^^^^^^^^^^^^^^^^^?
-----------------------------------------------------------------------------
# ipmitool channel info 1
Channel 0x1 info:
Channel Medium Type : 802.3 LAN
Channel Protocol Type : IPMB-1.0
Session Support : multi-session
Active Session Count : 0
Protocol Vendor ID : 7154
Volatile(active) Settings
Alerting : enabled
Per-message Auth : enabled
User Level Auth : enabled
Access Mode : always available
Non-Volatile Settings
Alerting : enabled
Per-message Auth : enabled
User Level Auth : enabled
Access Mode : always available
-----------------------------------------------------------------------------
# ipmitool user list 1
ID Name Callin Link Auth IPMI Msg Channel Priv Limit
2 ADMIN true true true ADMINISTRATOR
3 _ipmi_1 true true true ADMINISTRATOR
-----------------------------------------------------------------------------
# ipmitool -I lan -H 85.x.x.x -U ADMIN -E chassis status
Unable to read password from environment
Password:
Error: Unable to establish LAN session
ipmi_lan_send_cmd failed to open intf
Error sending Chassis Status command
-----------------------------------------------------------------------------
# ipmitool -I lanplus -H 85.x.x.x -U ADMIN -E chassis status
Unable to read password from environment
Password:
Error: Unable to establish IPMI v2 / RMCP+ session
Error sending Chassis Status command
-----------------------------------------------------------------------------
Supermicro IPMIView2 does not detect it either.
Regards,
Daniel Toma
-------------------------------------------------------------------------
Using Tomcat but need to do more? Need to support web services, security?
Get stuff done quickly with pre-integrated technology to make your job easier
Download IBM WebSphere Application Server v.1.0.1 based on Apache Geronimo
http://sel.as-us.falkag.net/sel?cmd=lnk&kid=120709&bid=263057&dat=121642
_______________________________________________
Ipmitool-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/ipmitool-devel