https://issues.apache.org/jira/browse/FLINK-7337?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16117176#comment-16117176
 ] 

ASF GitHub Bot commented on FLINK-7337:
---------------------------------------

Github user fhueske commented on a diff in the pull request:

    https://github.com/apache/flink/pull/4488#discussion_r131750828
  
    --- Diff: 
flink-libraries/flink-table/src/main/scala/org/apache/flink/table/plan/nodes/datastream/DataStreamGroupWindowAggregate.scala
 ---
    @@ -148,6 +142,20 @@ class DataStreamGroupWindowAggregate(
             "state size. You may specify a retention time of 0 to not clean up 
the state.")
         }
     
    +    val timestampedInput = if (isRowtimeAttribute(window.timeAttribute)) {
    +      // copy the window rowtime attribute into the StreamRecord timestamp 
field
    +      val timeAttribute = 
window.timeAttribute.asInstanceOf[ResolvedFieldReference].name
    +      val timeIdx = inputSchema.logicalFieldNames.indexOf(timeAttribute)
    --- End diff --
    
    Yes, in fact we can only do it like this because logical and physical type 
are the same. Otherwise, we would need to adjust the index.
    
    I'll clean up `RowSchema` a bit more to remove the distinction of logical 
and physical types.


> Refactor handling of time indicator attributes
> ----------------------------------------------
>
>                 Key: FLINK-7337
>                 URL: https://issues.apache.org/jira/browse/FLINK-7337
>             Project: Flink
>          Issue Type: Improvement
>          Components: Table API & SQL
>    Affects Versions: 1.4.0
>            Reporter: Fabian Hueske
>            Assignee: Fabian Hueske
>
> After a [discussion on the dev mailing 
> list|https://lists.apache.org/thread.html/735d55f9022df8ff73566a9f1553e14be94f8443986ad46559b35869@%3Cdev.flink.apache.org%3E]
>  I propose the following changes to the current handling of time indicator 
> attributes:
> * Remove the separation of logical and physical row type.
> ** Hold the event-time timestamp as regular Long field in Row
> ** Represent the processing-time indicator type as a null-valued field in Row 
> (1 bit overhead)
> * Remove materialization of event-time timestamps because timestamp is 
> already accessible in Row.
> * Add {{ProcessFunction}} to set timestamp into the timestamp field of a 
> {{StreamRecord}}.



--
This message was sent by Atlassian JIRA
(v6.4.14#64029)

Reply via email to