https://issues.apache.org/jira/browse/FLINK-2793?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14945117#comment-14945117
]
ASF GitHub Bot commented on FLINK-2793:
---------------------------------------
Github user tillrohrmann commented on a diff in the pull request:
https://github.com/apache/flink/pull/1202#discussion_r41272107
--- Diff:
flink-runtime-web/src/main/java/org/apache/flink/runtime/webmonitor/JobManagerArchiveRetriever.java
---
@@ -47,51 +60,160 @@
private final FiniteDuration timeout;
private final WebMonitor webMonitor;
+ /** Pattern to extract the host from an remote Akka URL */
+ private final Pattern hostFromLeaderAddressPattern =
Pattern.compile("^.+@(.+):([0-9]+)/user/.+$");
+
+ /** The JobManager Akka URL associated with this JobManager */
+ private volatile String jobManagerAkkaUrl;
+
/** will be written and read concurrently */
private volatile ActorGateway jobManagerGateway;
private volatile ActorGateway archiveGateway;
+ private volatile String redirectWebMonitorAddress;
public JobManagerArchiveRetriever(
WebMonitor webMonitor,
ActorSystem actorSystem,
FiniteDuration lookupTimeout,
FiniteDuration timeout) {
- this.webMonitor = webMonitor;
- this.actorSystem = actorSystem;
- this.lookupTimeout = lookupTimeout;
- this.timeout = timeout;
+
+ this.webMonitor = checkNotNull(webMonitor);
+ this.actorSystem = checkNotNull(actorSystem);
+ this.lookupTimeout = checkNotNull(lookupTimeout);
+ this.timeout = checkNotNull(timeout);
+ }
+
+ /**
+ * Associates this instance with the job manager identified by the
given URL.
+ *
+ * <p>This has to match the URL retrieved by the leader retrieval
service. In tests setups you
+ * have to make sure to use the correct type of URLs.
+ */
+ public void setJobManagerAkkaUrlAndRetrieveGateway(String
jobManagerAkkaUrl) throws Exception {
--- End diff --
Actually, I meant to get rid of this extra redirect logic here.
> Redirect to leading JobManager web fronted in non-standalone mode
> -----------------------------------------------------------------
>
> Key: FLINK-2793
> URL: https://issues.apache.org/jira/browse/FLINK-2793
> Project: Flink
> Issue Type: Improvement
> Components: JobManager
> Affects Versions: 1.0
> Reporter: Ufuk Celebi
> Assignee: Ufuk Celebi
>
> In case of a non-standalone recovery mode, the job manager frontend of
> non-leading job managers prints the job manager information of its associated
> job manager. Because the job manager is not leading, nothing shows up.
> The web frontend cannot directly communicate with the leading job manager,
> because many job manager structures like the execution graph are not
> serializable.
> A work around is to redirect to the web frontend of the leading job manager.
> This makes sure that all interesting information is presented.
--
This message was sent by Atlassian JIRA