JING ZHANG commented on FLINK-22781:
------------------------------------
[~lzljs3620320] I agree with you. It's better to split the issue into two sub
issues:
# Fix bug in `WindowOperator` not emit data if the counter is 0, which is in
progressed now.
# Find an elegant solution to define behavior(how to coordinate three relative
configuration: allow lateness, state TTL and enable late-fire emit) for
WindowAggregate which works on Changlog with primary key or other upsert
source. I would start a discussion later this week.
> Incorrect result for group window aggregate when mini-batch is enabled
> ----------------------------------------------------------------------
>
> Key: FLINK-22781
> URL: https://issues.apache.org/jira/browse/FLINK-22781
> Project: Flink
> Issue Type: Bug
> Components: Table SQL / Planner
> Affects Versions: 1.14.0
> Reporter: godfrey he
> Assignee: JING ZHANG
> Priority: Critical
> Labels: pull-request-available
> Fix For: 1.14.0
>
>
> We can reproduce this issue through adding the following code to
> {{GroupWindowITCase#testWindowAggregateOnUpsertSource}} method:
> {code:java}
> tEnv.getConfig.getConfiguration.setBoolean(
> ExecutionConfigOptions.TABLE_EXEC_MINIBATCH_ENABLED, true)
> tEnv.getConfig.getConfiguration.set(
> ExecutionConfigOptions.TABLE_EXEC_MINIBATCH_ALLOW_LATENCY,
> Duration.ofSeconds(1))
> tEnv.getConfig.getConfiguration.setLong(
> ExecutionConfigOptions.TABLE_EXEC_MINIBATCH_SIZE, 10L)
> {code}
> The reason is the group window without any data (the data may be retracted)
> should not send any record.
--
This message was sent by Atlassian Jira