https://issues.apache.org/jira/browse/TRAFODION-2385?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16037523#comment-16037523
]
ASF GitHub Bot commented on TRAFODION-2385:
-------------------------------------------
Github user DaveBirdsall commented on a diff in the pull request:
https://github.com/apache/incubator-trafodion/pull/1110#discussion_r120200329
--- Diff: win-odbc64/odbcclient/drvr35/cdesc.cpp ---
@@ -2277,7 +2277,8 @@ SQLRETURN CDesc::BuildValueList(CStmt *pHandle,
//AMR - changed this pointer ty
if(IPDDescRecPtr->m_ODBCDataType == SQL_VARCHAR
||
IPDDescRecPtr->m_ODBCDataType ==
SQL_LONGVARCHAR ||
- IPDDescRecPtr->m_ODBCDataType == SQL_CHAR)
+ IPDDescRecPtr->m_ODBCDataType == SQL_CHAR &&
+ IPDDescRecPtr->m_SQLDataType !=
SQLTYPECODE_BOOLEAN)
--- End diff --
Same comment as above
> Add support in clients for boolean, tinyint, largeint unsigned datatypes
> ------------------------------------------------------------------------
>
> Key: TRAFODION-2385
> URL: https://issues.apache.org/jira/browse/TRAFODION-2385
> Project: Apache Trafodion
> Issue Type: New Feature
> Components: connectivity-general
> Reporter: Anoop Sharma
> Fix For: 2.1-incubating
>
>
> Support for new datatypes was added for tinyint, boolean, largeint unsigned
> in sql engine.
> Those are tracked by following jiras:
> JIRA TRAFODION-2086 Add support for largeint unsigned datatype
> JIRA TRAFODION-2099 Add support for Boolean datatype
> JIRA TRAFODION-2060 Add support for native tinyint datatype
> Connectivity clients (odbc, jdbc t2/t4, linux, windows, trafci) need to
> enhanced to add this support. There may also be some work needed
> in mxosrvr layer. Until that is done, these datatypes cannot be used
> for reading values or input params from these clients.
> For now, these datatypes are converted to equivalent datatypes before
> input/output from clients.
> To enable these datatypes, use these cqds:
> For tinyint:
> cqd traf_tinyint_return_values 'ON';
> cqd traf_tinyint_input_params 'ON';
>
> For boolean:
> cqd traf_boolean_io 'ON';
> For unsigned largeint:
> cqd traf_largeint_unsigned_io 'ON';
> These cqds are turned ON when request comes in from sqlci.
> Once support for these datatypes is added to clients, they will be turned
> on by default.
> core/sql/regress/seabase/TEST003 contains examples of usage of these
> datatypes. First cut should be to make sure they work from trafci/jdbcT4.
--
This message was sent by Atlassian JIRA
(v6.3.15#6346)